Abstract

We evaluated the COBAS AMPLICOR (CA) PCR system (Roche Diagnostic Systems) designed for automated PCR amplification and detection of nucleic acids from infectious agents in clinical samples. The Roche AMPLICOR microwell plate (MWP) PCR was the reference method. CA amplifies target nucleic acid, captures the biotinylated amplification products by using magnetic particles coated with specific oligonucleotide probes, and detects the bound products colorimetrically. For Mycobacterium tuberculosis, the correlation of the results of CA tests with those of MWP tests was 100% with 230 samples, including 20 culture-positive samples. For hepatitis C virus, the correlation was 100% with 214 samples, including 60 positive samples. MultiPlex CA analysis of 199 cervical specimens for Chlamydia trachomatis, Neisseria gonorrhoeae, and the internal control gave 100% concordance. These samples included 19 C. trachomatis and 3 N. gonorrhoeae culture-positive samples. Overall, the agreement between PCR methods for all 842 comparisons was 100%. Compared with culture, the sensitivities of the assays for C. trachomatis and M tuberculosis were > or = 95%. After spiking alternating amplification tubes in the CA system with 10(14) copies of the Chlamydia amplicon per ml, we were unable to demonstrate any carryover cross-contamination of negative samples. Using the criteria of the College of American Pathologists workload recording method, we found that the total hands-on time to produce CA PCR results was 4.4, 7.9, and 3.3 min for M. tuberculosis, hepatis C virus, and the MultiPlexed assay for chlamydia plus gonorrhea and an internal control, respectively. The CA system brings true PCR automation to laboratories. In addition to the accuracy of automated results, the CA system provides labor savings, provides containment of the amplification and detection components of PCR, and supports both MultiPlex amplification and sequential algorithm (ReFlex) detection of analytes.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference15 articles.

1. Efficacy of PCR-microwell plate hybridization method (Amplicor Mycobacterium) for detection of M. tuberculosis, M. avium and/or M. intracellulare in clinical specimens;Aoki M.;Kekkaku,1994

2. Clinical evaluation of a new polymerase chain reaction assay for detection of Chlamydia trachomatis endocervical specimens;Bass C. A.;J. Clin. Microbiol.,1993

3. Evaluation of Amplicor PCR for direct detection of Mycobacterium tuberculosis from sputum specimens;Beavis K. G. M. B.;J. Clin. Microbiol.,1995

4. College of American Pathologists. 1992. Workload recording method and personnel management manual 1992 edition. College of American Pathologists Northfield Ill.

5. Comparison of amplified Mycobacterium tuberculosis Direct Test (MTD), Amplicor Mycobacteria kit (Amplicor) and PCR method for detection Mycobacterium tuberculosis in clinical specimens;Goto M.;Kansenshogaku Zasshi J. Jpn. Assoc. Infect. Dis.,1995

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3