Safety and pharmacokinetics of rimantadine small-particle aerosol

Author:

Atmar R L1,Greenberg S B1,Quarles J M1,Wilson S Z1,Tyler B1,Feldman S1,Couch R B1

Affiliation:

1. Influenza Research Center, Baylor College of Medicine, Houston, Texas.

Abstract

The safety and pharmacokinetics of rimantadine administered by small-particle aerosol were assessed in healthy adults and adults with acute influenza virus infection. Aerosolized rimantadine delivered at a concentration of 40 micrograms/liter of air was associated with nasal burning and irritation in normal volunteers. A concentration of 20 micrograms/liter of air was well tolerated for up to 12 h by normal volunteers and was not associated with any changes in pulmonary function, as measured by routine spirometry, plethysmography, or diffusion capacity of carbon monoxide. Mean peak levels of drug in serum were approximately 10-fold lower after 12 h of aerosol administration than they were after oral administration of 200 mg (29.7 versus 255 ng/ml, respectively), while mean nasal wash levels were approximately 100-fold higher (6,650 versus 66.6 ng/ml, respectively). Elimination half-lives were similar after both aerosol and oral administration (24.1 and 25.2 h, respectively), and rimantadine urinary excretion was less than 1% per 24 h in both groups. Twenty micrograms of aerosolized rimantadine per liter of air given 12 h daily for 3 days to nine adults with acute influenza virus infection was well tolerated. Levels in plasma after 12 h of aerosol inhalation were similar to those in normal volunteers, but were higher at the end of the third treatment than they were at the end of the first treatment (88.3 versus 47.9 ng/ml, respectively). Thus, rimantadine delivered via small-particle aerosol at a dose of 20 micrograms/liter of air was well tolerated in normal volunteers and in those with acute influenza and was associated with high local concentrations.

Publisher

American Society for Microbiology

Subject

Infectious Diseases,Pharmacology (medical),Pharmacology

Reference35 articles.

1. American Institute of Architects Committee on Architecture for Health. 1987. Guidelines for construction and equipment of hospital and medical facilities p. 50. The American Institute of Architects Press Washington D.C.

2. ATS statement-Snowbird Workshop on standardization of spirometry;American Thoracic Society;Am. Rev. Respir. Dis.,1979

3. Maintenance of viability and comparison of identification methods for influenza and other respiratory viruses of humans;Baxter B. D.;J. Clin. Microbiol.,1977

4. Genetic basis of resistance to rimantadine emerging during treatment of influenza virus infection;Belshe R. B.;J. Virol.,1988

5. Anti-influenza A virus activity of amantadine hydrochloride and rimantadine hydrochloride in ferret tracheal ciliated epithelium;Burlington D. B.;Antimicrob. Agents Chemother.,1982

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3