Evaluation of the BD PHOENIX Automated Microbiology System for Detection of Methicillin Resistance in Coagulase-Negative Staphylococci

Author:

Horstkotte Matthias A.1,Knobloch Johannes K.-M.1,Rohde Holger1,Dobinsky Sabine1,Mack Dietrich12

Affiliation:

1. Institut für Infektionsmedizin, Zentrum für Klinisch-Theoretische Medizin, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany

2. Chair of Medical Microbiology and Infectious Diseases, The Clinical School, University of Wales Swansea, Swansea, United Kingdom

Abstract

ABSTRACT The new BD PHOENIX automated microbiology system (Becton Dickinson Diagnostic Systems, Sparks, Md.) is designed for automated rapid antimicrobial susceptibility testing and identification of clinically relevant bacteria. In our study, the accuracy and speed of the BD PHOENIX oxacillin MIC determination for detecting methicillin resistance was evaluated for 200 clinical isolates of coagulase-negative staphylococci (CoNS). Compared to mecA PCR, the BD PHOENIX system detected methicillin resistance with a sensitivity of 99.2%. According to the actual NCCLS oxacillin MIC breakpoint of ≥0.5 μg/ml, the specificity was only 64.9%, attributable to false-positive results in 26 mecA -negative strains, including 16 non- Staphylococcus epidermidis strains. Alternative oxacillin breakpoints of ≥1, ≥2, and ≥4 μg/ml resulted in increased specificities of 83.8, 94.6, and 100% and high sensitivities of 99.2, 99.2, and 96.7%, respectively. Similarly, NCCLS broth microdilution oxacillin MICs exhibited a sensitivity of 100% but a low degree of specificity. However, the previous oxacillin MIC breakpoint of ≥4 μg/ml performed with a sensitivity of 98.4% and a specificity of 98.7%. BD PHOENIX oxacillin MIC results were available after 9 h for 40.5% of the examined CoNS strains and were completed after 17 h. Our results revealed the high reliability of the BD PHOENIX system as a phenotypic method for detection of resistance to oxacillin in mecA -positive CoNS. However, for the improvement of specificity, reevaluation of the optimal oxacillin MIC breakpoint for CoNS appears to be necessary.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3