Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Assay for Diagnosis of Cutaneous and Visceral Leishmaniasis

Author:

Adams Emily Rebecca1,Schoone Gerard2,Versteeg Inge2,Gomez Maria Adelaida34,Diro Ermias5,Mori Yasuyoshi6,Perlee Desiree2,Downing Tim7,Saravia Nancy34,Assaye Ashenafi8,Hailu Asrat8,Albertini Audrey9,Ndung'u Joseph Mathu9,Schallig Henk2

Affiliation:

1. Research Centre for Drugs and Diagnostics, Parasitology Department, Liverpool School of Tropical Medicine, Liverpool, United Kingdom

2. Academic Medical Centre, Department of Medical Microbiology, Parasitology Unit, Amsterdam, The Netherlands

3. Centro Internacional de Entrenamiento e Investigaciones Médicas, CIDEIM, Cali, Colombia

4. Universidad Icesi, Cali, Colombia

5. University of Gondar, Gondar, Ethiopia

6. Eiken Chemical Company, Tokyo, Japan

7. Parasite Genomics, Wellcome Trust Sanger Institute, Wellcome Trust Genome Campus, Hinxton, United Kingdom

8. University of Addis Ababa, School of Medicine, Addis Ababa, Ethiopia

9. Foundation for Innovative New Diagnostics, Geneva, Switzerland

Abstract

ABSTRACT A novel pan- Leishmania loop-mediated isothermal amplification (LAMP) assay for the diagnosis of cutaneous and visceral leishmaniasis (CL and VL) that can be used in near-patient settings was developed. Primers were designed based on the 18S ribosomal DNA (rDNA) and the conserved region of minicircle kinetoplast DNA (kDNA), selected on the basis of high copy number. LAMP assays were evaluated for CL diagnosis in a prospective cohort trial of 105 patients in southwest Colombia. Lesion swab samples from CL suspects were collected and were tested using the LAMP assay, and the results were compared to those of a composite reference of microscopy and/or culture in order to calculate diagnostic accuracy. LAMP assays were tested on samples (including whole blood, peripheral blood mononuclear cells, and buffy coat) from 50 suspected VL patients from Ethiopia. Diagnostic accuracy was calculated against a reference standard of microscopy of splenic or bone marrow aspirates. To calculate analytical specificity, 100 clinical samples and isolates from fever-causing pathogens, including malaria parasites, arboviruses, and bacteria, were tested. We found that the LAMP assay had a sensitivity of 95% (95% confidence interval [CI], 87.2% to 98.5%) and a specificity of 86% (95% CI, 67.3% to 95.9%) for the diagnosis of CL. With VL suspects, the sensitivity of the LAMP assay was 92% (95% CI, 74.9% to 99.1%) and its specificity was 100% (95% CI, 85.8% to 100%) in whole blood. For CL, the LAMP assay is a sensitive tool for diagnosis and requires less equipment, time, and expertise than alternative CL diagnostics. For VL, the LAMP assay using a minimally invasive sample is more sensitive than the gold standard. Analytical specificity was 100%.

Funder

TiPharma

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3