Abstract
Isolation techniques with membrane-filtered potable water samples resulted in the isolation of potentially pathogenic high-catalase strains of Mycobacterium kansasii from 8 of 19 representative outlets in a small central Texas town. Mycobacterium gordonae was isolated from all samples, and Mycobacterium fortuitum was isolated from two samples. Data on chlorine levels are presented along with a possible explanation for the unusually high numbers of mycobacteria in these potable water samples. Findings suggest that water is a source of M. kansasii and may be an important link in the epidemiological picture of the disease.
Publisher
American Society for Microbiology
Reference11 articles.
1. The demographic study of disease due to Mycobacterium kansasii or Mvcobacterium intracellulare-aulium in Texas;Ahn C. H.;Chest,1979
2. The isolation of high catalase Mycobacterium kansasii from tap water;Bailey R. K.;Am. Rev. Respir. Dis.,1970
3. The ecology of the atypical mycobacteria;Chapman J. S.;Arch. Environ. Health,1971
4. Chapman J. S. 1977. The atypical mvcobacteria and human mycobacteriosis p. 56. Plenum Publishing Corp. New York.
5. Water as a source of potentially pathogenic mycobacteria;Goslee S.;Am. Rev. Respir. Dis.,1976
Cited by
54 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献