Evaluation of a Low-Cost Electrostatic Dust Fall Collector for Indoor Air Endotoxin Exposure Assessment
-
Published:2008-09-15
Issue:18
Volume:74
Page:5621-5627
-
ISSN:0099-2240
-
Container-title:Applied and Environmental Microbiology
-
language:en
-
Short-container-title:Appl Environ Microbiol
Author:
Noss Ilka1, Wouters Inge M.1, Visser Maaike1, Heederik Dick J. J.1, Thorne Peter S.2, Brunekreef Bert1, Doekes Gert1
Affiliation:
1. Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands 2. Environmental Health Sciences Research Center, University of Iowa, Iowa City, Iowa
Abstract
ABSTRACT
Exposure to endotoxin in home environments has become a key issue in asthma and allergy research. Most studies have analyzed floor or mattress dust endotoxin, but its validity as a proxy for airborne exposure is unknown, while active airborne dust sampling is not feasible in large-scale population studies because of logistic and financial limitations. We therefore developed and evaluated a simple passive airborne dust collection method for airborne endotoxin exposure assessment. We explored an electrostatic dust fall collector (EDC), consisting of a 42- by 29.6-cm-sized folder with four electrostatic cloths exposed to the air. The EDC was tested during two 14-day periods in seven nonfarm and nine farm homes and in farm stables. In parallel, active airborne dust sampling was performed with Harvard impactors and floor dust collected by vacuuming, using nylon sampling socks. The endotoxin levels could be measured in all EDC cloth extracts. The levels (in EU/m
2
) between EDCs used simultaneously or in different sampling periods in the same home correlated strongly (
r
> 0.8). EDC endotoxin also correlated moderately to strongly (
r
= 0.6 to 0.8) with the endotoxin measured by active airborne dust sampling and living room floor dust sampling and—in farm homes—with the endotoxin captured by the EDC in stables. In contrast, endotoxin levels measured by floor dust sampling showed only a poor correlation with the levels measured by active airborne dust sampling. We therefore conclude that measuring endotoxin levels with the EDC is a valid measure of average airborne endotoxin exposure, while reproducibility over time is at least equivalent to that of reservoir dust analyses.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference24 articles.
1. Antens, C. J., M. Oldenwening, A. Wolse, U. Gehring, H. A. Smit, R. C. Aalberse, M. Kerkhof, J. Gerritsen, J. C. de Jongste, and B. Brunekreef. 2006. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years. Clin. Exp. Allergy36:1525-1531. 2. Custis, N. J., J. A. Woodfolk, J. W. Vaughan, and T. A. Platts-Mills. 2003. Quantitative measurement of airborne allergens from dust mites, dogs, and cats using an ion-charging device. Clin. Exp. Allergy33:986-991. 3. Custovic, A., B. Simpson, A. Simpson, C. Hallam, M. Craven, and A. Woodcock. 1999. Relationship between mite, cat, and dog allergens in reservoir dust and ambient air. Allergy54:612-616. 4. Fahlbusch, B., A. Koch, J. Douwes, W. Bischof, U. Gehring, K. Richter, H. E. Wichmann, and J. Heinrich. 2003. The effect of storage on allergen and microbial agent levels in frozen house dust. Allergy58:150-153. 5. Heinrich, J., B. Holscher, J. Douwes, K. Richter, A. Koch, W. Bischof, B. Fahlbusch, R. W. Kinne, and H. E. Wichmann. 2003. Reproducibility of allergen, endotoxin and fungi measurements in the indoor environment. J. Expo. Anal. Environ. Epidemiol.13:152-160.