Fluorescent Treponemal Antibody Absorption Double-Staining Test Evaluation

Author:

Farshy Carol E.1,Kennedy Edward J.2,Hunter Elizabeth F.1,Larsen Sandra A.1

Affiliation:

1. Treponemal Research and Immunology Laboratory, Sexually Transmitted Diseases Laboratory Program, Center for Infectious Diseases, Centers for Disease Control, Atlanta, Georgia 30333

2. Laboratory Improvement Program Office, Centers for Disease Control, Atlanta, Georgia 30333

Abstract

The fluorescent treponemal antibody absorption (FTA-ABS) double-staining (DS) test has been developed for microscopes equipped with incident illumination, and the procedure offers many advantages over the FTA-ABS test when tests are performed with this equipment. In this study, 346 fresh sera, including 35 from patients with syphilis, were evaluated by the FTA-ABS DS test. Parameters for investigation included two readers, each using a different microscope; a new FTA-ABS DS test reporting system; sera heated at 56°C for 30 min versus unheated sera; and sera retested after at least 2 weeks of freezer storage. Agreement for FTA-ABS DS test readings between the two microscopes was 99%. Between-test agreement for the FTA-ABS test with the conventional reporting system and the FTA-ABS DS test with the new reporting system was 95%. Sensitivity calculations based on reactivity for the 35 syphilis sera were 94% for the FTA-ABS DS test and 91% for the FTA-ABS test. Specificity calculations based on non-reactivity of nonsyphilis sera were 98% for the FTA-ABS DS test and 93% for the FTA-ABS test. Differences in percentages appeared to be related to borderline readings in the FTA-ABS test. For example, if the same reporting system was used for the reference FTA-ABS test, the specificity was 97%. When sera were examined within 48 h, no difference was observed in results obtained with heated and unheated sera. Sera frozen for 2 weeks showed comparable results in the FTA-ABS DS test and the FTA-ABS test. These findings strongly support the recommendation that the FTA-ABS DS test be accepted as a confirmatory test for syphilis. The new reporting system for the FTA-ABS DS test would be advantageous for the reference FTA-ABS procedure.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference7 articles.

1. Problems affecting performance of the fluorescent treponemal antibody-absorption test for syphilis;Hunter E. F.;J. Clin. Microbiol.,1979

2. Double-staining procedure for the fluorescent treponemal antibody absorption (FTA-ABS) test;Hunter E. F.;Br. J. Vener. Dis.,1979

3. Fluorescent treponemal antibody-absorption double-staining procedure;Hunter E. F.;J. Clin. Microbiol.,1981

4. Heated versus unheated sera in a microhemagglutination assay for antibodies to Treponema pallidum;Larsen S. A.;J. Clin. Microbiol.,1978

5. Further studies with the fluorescent treponemal antibody-absorption double-staining procedure;Mote P. T.;J. Clin. Microbiol.,1980

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3