Performance of the BioPlex 2200 Flow Immunoassay in Critical Cases of Serodiagnosis of Toxoplasmosis

Author:

Guigue Nicolas1,Menotti Jean1,Hamane Samia1,Derouin Francis1,Garin Yves Jean-François1

Affiliation:

1. Laboratoire de Parasitologie et de Mycologie, Hôpital Saint Louis, Assistance Publique-Hôpitaux de Paris et Université Paris Diderot, Sorbonne Paris Cité, Paris, France

Abstract

ABSTRACT The BioPlex 2200 automated analyzer (Bio-Rad Laboratories, Hercules, CA) is a recently developed multiplex analyzer that enables the detection of anti- Toxoplasma , -rubella, and -cytomegalovirus antibodies in the same assay. The aim of this study was to compare this new technology (using the BioPlex 2200 ToRC IgG/IgM kit) in critical cases of serodiagnosis of toxoplasmosis (acute, chronic, or congenital infections and cases with discrepant results) to the technologies used in our routine practice, i.e., the Platelia IgG/IgM enzyme-linked immunosorbent assays (ELISAs) (Bio-Rad Laboratories) and the Toxo-Screen direct agglutination assay (bioMérieux, Lyon, France). Overall, most cases of false-positive/negative results obtained with the Platelia IgG or Toxo-Screen assay were corrected by the BioPlex 2200 ToRC IgG (87.5%). Furthermore, the analysis of 35 sequences of sera showed a trend toward a more rapid decrease of IgM titers by BioPlex 2200 than by Platelia. These results for IgM detection can be explained by a weaker detection of residual IgM. Indeed, among 23 serum samples from patients with probable past infection with long-lasting IgM (Platelia M positive and IgG avidity index, ≥0.5), the BioPlex 2200 Toxoplasma IgM assay was positive for only 11 serum samples. In our panel of critical cases comprising 156 serum and 6 cord blood samples from 103 patients with acute, chronic, or congenital infection, the BioPlex 2200 IgG assay was a sensitive (97.8%) and specific (91.3%) method for IgG detection. The high specificity (97.4%) of IgM detection combined with the shorter kinetics of IgM titers may considerably reduce the number of residual IgM detections, thus yielding more precise diagnoses of acute infections.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3