Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates

Author:

Ackerman S B,Kelley E A

Abstract

The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference10 articles.

1. Practical colorimeter for direct measurement of microplates in enzyme immunoassay systems;Clem T. R.;J. Clin. Microbiol.,1978

2. Enzyme-linked immunosorbent assay (ELISA). Quantitative assay of immunoglobulin G;Engvail E.;Immunochemistry,1971

3. Multichannel, probe colorimeter for use with the micro-ELISA test, which makes use of disposable flat-bottom microhemagglutination plates;McMurray C. H.;Clin. Chem. N. Y.,1979

4. Fiber-optic colorimetry;Munsnger R. A.;Electro-Opt. Syst. Des.,1981

5. Heterogeneous enzyme immunoassay;O'Betrne A. J.;J. Histochem. Cytochem.,1979

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Chemical Sensing with Fiberoptic Devices;Biosensors with Fiberoptics;1991

2. Bibliography;Enzyme Immunodiagnosis;1986

3. Non-Electrode Biosensors in Clinical Biochemistry;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;1985-11

4. References;Laboratory Techniques in Biochemistry and Molecular Biology;1985