Evaluation of test media for routine monitoring of Escherichia coli in nonpotable waters

Author:

Gaudet I D1,Florence L Z1,Coleman R N1

Affiliation:

1. Alberta Environmental Centre, Vegreville, Canada. irene@aec.arc.ab.ca

Abstract

Six test media, m-TEC, m-TEC with 4-methylumbelliferyl-beta-D-glucuronide (MUG), lauryl tryptose agar (LTA) with MUG, LTA with 5-bromo-4-chloro-3-indolyl-beta-D-glucuronide (X-Glue), EC medium with MUG, and lauryl tryptose broth with MUG, were evaluated for their usefulness in enumerating Escherichia coli in nonpotable waters on a routine basis. The media were chosen for their case of interpretation of target colonies, ability to allow enumeration at low and high concentrations, and ability to inhibit nontarget microorganisms. The recoveries on the test media were compared with those on three reference media, R2A, m-FC, and m-Endo, by analysis of spiked samples of filter-sterilized waters. The test media were then further tested for their ability to differentiate nontarget but closely related microorganisms. Statistical analysis indicated that the best recoveries were obtained with lauryl tryptose agar with added MUG and X-Gluc. The media were then tested with surface waters that could be expected to have high levels of total and fecal coliforms along with Escherichia coli.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

Reference18 articles.

1. American Public Health Association American Water Works Association and Water Pollution Control Federation. 1992. Standard methods for the examination of water and wastewater 18th ed. American Public Health Association Washington D.C.

2. American Society for Testing and Materials. 1994. Annual book of ASTM standards. Water and environmental technology volume 11.02 Water II. American Society for Testing and Materials Philadelphia.

3. Bordner R. H. 1991. Test methods for Escherichia coli in drinking water. EC medium with MUG tube procedure nutrient agar with MUG membrane filter procedure. EPA PB91-234591. U.S. Environmental Protection Agency Washington D.C.

4. New medium for the simultaneous detection of total coliforms and Escherichia coli in water;Brenner K. P.;Appl. Environ. Microbiol.,1993

5. Comparative study of commercial 4-methylumberlliferyl-~-D-glucuronide preparations with the Standard Methods membrane filtration fecal coliform test for the detection of Escherichia coli in water samples;Clark D. L.;Appl. Environ. Microbiol.,1991

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Bacterial transmission and colonization in activated carbon block (ACB) point-of-use (PoU) filters;Environmental Science: Water Research & Technology;2021

2. Photocatalytic disinfection of Escherichia coli using TiO2 P25 and Cu-doped TiO2;Journal of Industrial and Engineering Chemistry;2015-08

3. Microbial Characterisation of the Sava River;The Handbook of Environmental Chemistry;2014-10-03

4. Variability in the Characterization of Total Coliforms, Fecal Coliforms and Escherichia coli in Recreational Water Supplies of North Mississippi, USA;Bulletin of Environmental Contamination and Toxicology;2014-06-22

5. References;Wastewater Microbiology;2010-11-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3