Comparative Analysis of the Diagnostic Performance of Six Major Echinococcus granulosus Antigens Assessed in a Double-Blind, Randomized Multicenter Study

Author:

Lorenzo Carmen1,Ferreira Henrique B.2,Monteiro Karina M.2,Rosenzvit Mara3,Kamenetzky Laura3,García Hector H.4,Vasquez Yessika4,Naquira Cesar5,Sánchez Elizabeth5,Lorca Myriam6,Contreras María6,Last Jerry A.7,González-Sapienza Gualberto G.1

Affiliation:

1. Cátedra de Inmunología, Facultad de Química, UDELAR, Instituto de Higiene, Montevideo, Uruguay

2. Laboratório de Biologia Molecular de Cestódeos, Centro de Biotecnología, Universidade Federal do Rio Grande do Sul, Rio Grande do Sul, Brazil

3. Departamento de Parasitología, Instituto Nacional de Enfermedades Infecciosas, ANLIS “Dr. Carlos G. Malbrán,” Buenos Aires, Argentina

4. Departamento de Microbiología, Universidad Peruana Cayetano Heredia, Instituto de Ciencias Neurológicas, Lima, Peru

5. Laboratorio de Zoonosis, División de Parasitología, Instituto Nacional de Salud, Lima, Peru

6. Unidad de Parasitología, Facultad de Medicina, Universidad de Chile, Santiago de Chile, Chile

7. Department of Internal Medicine (Pulmonary), School of Medicine, University of California, Davis, California

Abstract

ABSTRACT The serodiagnosis of hydatid disease is a valuable instrument for clinical diagnosis and epidemiological surveillance of high-risk populations. In the past decade a wealth of reports on the diagnostic performance of numerous antigens have been produced. However, their diagnostic value has been estimated under different conditions, using different serum collection, therefore precluding their direct comparison. Here we report an unbiased comparison of the same batch of six major E. granulosus antigens, namely, hydatid cyst fluid (HCF), native antigen B (AgB), two recombinant AgB subunits, an AgB-derived synthetic peptide, and recombinant cytosolic malate dehydrogenase from E. granulosus (EgMDH), against the same serum collection. The double-blind analysis was performed using a standardized protocol and receiver operating characteristic (ROC) data analysis by a network of six South American laboratories. High intercenter reproducibility was attained, and the intralaboratory analysis allowed the comparative ranking of the antigen panel. HCF, AgB, and its AgB8/1 subunit exhibited equivalent diagnostic efficiencies, 81.4% ± 0.5%, 81.3% ± 0.6%, and 81.9% ± 2.0%, respectively; with a more favorable balance toward specificity in the case of the last antigen. The diagnostic efficiencies for the other three antigens were 76.8% ± 6.8%, 69.1% ± 2.7%, and 66.8% ± 2.1%, for the peptide, the AgB8/2 subunit, and the EgMDH, respectively. The study also included an analysis of batch-to-batch variation in the diagnostic performance of different HCF regional preparations. Based on these results, a suggested recommendation on the use of these antigens was drawn.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3