Comparison of the COBAS AMPLICOR MTB and BDProbeTec ET Assays for Detection of Mycobacterium tuberculosis in Respiratory Specimens

Author:

Goessens W. H. F.1,de Man P.2,Koeleman J. G. M.2,Luijendijk A.1,te Witt R.2,Endtz H. P.1,van Belkum A.1

Affiliation:

1. Erasmus MC, University Medical Center Rotterdam, Dept. of Medical Microbiology & Infectious Diseases, Rotterdam, The Netherlands

2. St. Franciscus Hospital, Dept. of Medical Microbiology, Rotterdam, The Netherlands

Abstract

ABSTRACT The performances of the BDProbeTec ET (Becton Dickinson) and COBAS AMPLICOR MTB (Roche) were retrospectively evaluated for detecting Mycobacterium tuberculosis complex in various respiratory specimens. The BACTEC and MGIT liquid culture system (Becton Dickinson) was used as a reference method. A total of 824 respiratory specimens, comprised of sputa, bronchoalveolar lavage fluid, and bronchial and tracheal aspirates from 580 patients, were evaluated. Out of 824 clinical specimens, 109 specimens from 43 patients were culture positive for M. tuberculosis . Of these 109 specimens, 67 were smear positive, 85 were positive by the COBAS AMPLICOR MTB test, and 94 were positive by the BDProbeTec ET. Of the 715 culture-negative specimens, 17 were positive by the auramine staining, 11 were positive by the COBAS AMPLICOR MTB test, and 12 were positive by the BDProbeTec ET. After discrepancy analysis and review of the patients' clinical data, 130 specimens from 50 patients were considered “true-positive” specimens. This resulted in the following sensitivities: microscopy, 61.5%; COBAS AMPLICOR MTB test, 78.0%; and BDProbeTec ET, 86.2%. The specificities of each system, based on the clinical diagnosis, were 99.7% for microscopy, 99.9% for the COBAS AMPLICOR MTB test, and 99.9% for the BDProbeTec ET. The data presented represent a considerable number of specimens evaluated with a considerable number of culture- and auramine-positive and culture-positive and auramine-negative results and therefore give a realistic view of how the data should be interpreted in a daily routine situation. Specifically, the data with regard to the culture-positive and auramine-negative specimens are useful, because in a routine situation, auramine-negative specimens are sometimes accepted, on clinical indications, to be analyzed by an amplification method.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3