Evaluation of Quantification of HIV-1 RNA Viral Load in Plasma and Dried Blood Spots by Use of the Semiautomated Cobas Amplicor Assay and the Fully Automated Cobas Ampliprep/TaqMan Assay, Version 2.0, in Kisumu, Kenya

Author:

Ouma Kenneth N.1,Basavaraju Sridhar V.2,Okonji Jully A.1,Williamson John3,Thomas Timothy K.3,Mills Lisa A.3,Nkengasong John N.4,Zeh Clement3

Affiliation:

1. Centre for Global Health Research, Kenya Medical Research Institute, Kisumu, Kenya

2. HIV Prevention Branch, Division of Global HIV/AIDS, Center for Global Health, Centers for Disease Control and Prevention, Atlanta, Georgia, USA

3. Division of HIV/AIDS Prevention, Centers for Disease Control and Prevention, Kisumu, Kenya

4. International Laboratory Branch, Division of Global HIV/AIDS, Center for Global Health, Centers for Disease Control and Prevention, Atlanta, Georgia, USA

Abstract

ABSTRACT In Kenya, HIV-1 viral load monitoring is commonly performed with the Cobas Amplicor using plasma specimens. Interest is growing in transitioning to real-time PCR (RT-PCR), such as the Cobas Ampliprep/Cobas TaqMan (CAP/CTM), using dried blood spots (DBS). Before implementation, direct evaluation of the two assays using DBS field specimens is required. This study compares the sensitivity, specificity, negative and positive predictive values (NPV and PPV, respectively), concordance, and agreement between HIV-1 viral load measurements using plasma and DBS specimens obtained from 512 HIV-1-infected pregnant females enrolled in the Kisumu Breastfeeding Study and tested with the Cobas Amplicor and CAP/CTM assays. The sensitivity and NPV of viral load detection in DBS specimens were higher with CAP/CTM (sensitivity, 100%; 95% confidence interval [CI], 99.1 to 100.0%; NPV, 100%; 95% CI, 59.0 to 100.0%) than the Cobas Amplicor (sensitivity, 96.6%; 95% CI, 94.3 to 98.1%; NPV, 58.8%; 95% CI, 40.7 to 75.4%). The PPVs were comparable between both assays when using DBS. The specificity of viral load detection in DBS specimens was lower with CAP/CTM (77.8%; 95% CI, 40.0 to 97.2%) than that of the Cobas Amplicor (95.2%; 95% CI, 76.2 to 99.9%). Good concordance and agreement were observed when paired plasma and DBS specimens were tested with both assays. Lower specificity with the CAP/CTM is likely due to proviral HIV-1 DNA amplification and lower detection limits with RT-PCR. However, the CAP/CTM has better sensitivity and higher throughput than the Cobas Amplicor. These findings suggest that DBS may be a suitable alternative to plasma when using RT-PCR, which could increase access to viral load monitoring in resource-limited settings.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference41 articles.

1. UNAIDS. 2010. UNAIDS report on the global AIDS epidemic 2010. UNAIDS Geneva Switzerland. www.unaids.org/globalreport/global_report.htm. Accessed 23 May 2011.

2. WHO. 2010. Antiretroviral therapy for HIV infection in adults and adolescents: recommendations for a public health approach. 2010 revision. WHO Geneva Switzerland. whqlibdoc.who.int/publications/2010/9789241599764_eng.pdf. Accessed 10 June 2011.

3. Immunologic criteria are poor predictors of virologic outcome: implications for HIV treatment monitoring in resource-limited settings;Rawizza HE;Clin. Infect. Dis,2011

4. Diagnosis of antiretroviral therapy failure in Malawi: poor performance of clinical and immunological WHO criteria;van Oosterhout JJ;Trop. Med. Int. Health,2009

5. Expanded highly active antiretroviral therapy coverage—a powerful strategy to curb progression to AIDS, death and new Infections;Anema A;Eur. Infect. Dis,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3