Affiliation:
1. Laboratoires Réunis Kutter-Lieners-Hastert, Junglinster, Luxembourg,1 and
2. Institut für Medizinische Virologie, Universitätskliniken Frankfurt, Frankfurt, Germany2
Abstract
ABSTRACT
In order to reduce the diagnostic window between the time of human immunodeficiency virus (HIV) infection and laboratory diagnosis, new screening enzyme-linked immunosorbent assays (ELISAs) which permit the simultaneous detection of HIV antigen and antibody have been developed. Two fourth-generation assays, HIV DUO (Biomérieux) and HIV Combi (Boehringer Mannheim), for the combined detection of HIV antigen and antibody, were compared with a third-generation assay (HIV-1/HIV-2 3rd Generation Plus enzyme immunoassay [EIA]; Abbott) and a p24 antigen test (HIV-1 Ag monoclonal; Abbott). A total of 17 seroconversion panels, 15 cell culture supernatants infected with different HIV type 1 (HIV-1) subtypes, and 255 potentially cross-reactive serum samples were tested. Ten seroconversions were detected an average of 8.1 days earlier with HIV DUO and 7.5 days earlier with HIV Combi than with the third-generation ELISA. Overall, in the 17 seroconversion panels tested, HIV DUO detected HIV-1 infection an average of 4.8 days and HIV Combi detected infection an average of 4.4 days earlier than HIV-1/HIV-2 3rd Generation Plus EIA. HIV antigen was detected with HIV DUO and HIV Combi in all of the 15 cell culture supernatants infected with different HIV-1 subtypes, including subtype O. With fourth-generation assays, considerably fewer false-positive results (
n
= 4 to 6) were obtained, in comparison with the third-generation EIA (
n
= 18). Fourth-generation assays permit an earlier diagnosis of HIV infection than third-generation antibody screening assays through the detection of p24 antigen, which may be present in serum samples from individuals with recent HIV infection prior to seroconversion.
Publisher
American Society for Microbiology
Reference17 articles.
1. Prevalence of human immunodeficiency virus type 1 p24 antigen in U.S. blood donors—an assessment of the efficacy of testing in donor screening;Alter H. J.;N. Engl. J. Med.,1990
2. Cost-effectiveness of expanded human immunodeficiency virus-testing protocols for donated blood;Aubuchon J. P.;Transfusion,1997
3. Performance of the Amplicor human immunodeficiency virus type 1 PCR and analysis of specimens with false-negative results
4. Bünung
H.
Trenkler
G.
Nicht-parametrierbare Methoden.
1978
Springer Verlag
Berlin Germany
5. Centers for Disease Control. 1989. Interpretation and use of the Western blot assay for serodiagnosis of human immunodeficiency virus type 1 infections. Morbid. Mortal. Weekly Rep. 38 (Suppl. S-7) : 1–7.
Cited by
117 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献