Validation of the Automated Reading and Incubation System with Sensititre Plates for Antimicrobial Susceptibility Testing

Author:

Chapin Kimberle C.1,Musgnug Michael C.1

Affiliation:

1. Department of Laboratory Medicine, Lahey Clinic Medical Center, Burlington, Massachusetts 01805

Abstract

ABSTRACT The present study compared the antimicrobial susceptibility testing (AST) results generated by the Automated Incubation and Reading System (ARIS) with custom Sensititre plates (TREK Diagnostic Systems, Cleveland, Ohio) and MicroScan PC10 GP and NUMIC10 GN plates interpreted with the WalkAway-96 system (Dade Behring, West Sacramento, Calif.) for gram-positive (GP) and gram-negative (GN) organisms as part of an in-house validation. A total of 326 isolates (3,689 antimicrobial agent-organism combinations) were evaluated. Sensititre plates were inoculated according to the instructions of the manufacturer with a suspension adjusted to a 0.5 McFarland standard, while the Prompt Inoculation System was used for the MicroScan plates. ARIS and the WalkAway system were used for automated reading of the Sensititre and MicroScan plates, respectively, at 18 to 24 h. The results were analyzed for essential (±1 twofold dilution) and categorical (sensitive, intermediate, or resistant) agreements. Plates that resulted in ARIS interpretations with major (falsely resistant) or very major (falsely susceptible) errors compared to the results obtained with the WalkAway system were read manually to corroborate instrument readings. Isolates for which very major or major errors were obtained and for which the results were not resolved by manual reading were retested in parallel. Isolates for which very major or major errors were obtained and for which the results were not resolved upon repeat testing were tested by the National Committee for Clinical Laboratory Standards M7-A5 frozen reference microdilution method. Essential agreement was 95.8% for 246 GN isolates. The following categorical error rates were obtained for the GN isolates: 1.3% minor errors, 0% major errors, and 0.4% very major errors. For 95 GP isolates, there was 93.5% essential agreement. Categorical error rates for GP isolates were 0.9% minor errors, 0.6% major errors, and 0.4% very major errors. ARIS-Sensititre is a diagnostic system feasible for use for automated AST in a clinical laboratory.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3