Affiliation:
1. Department of Microbiology and Immunology, Texas Tech University Health Sciences Center, Lubbock, Texas 79430
Abstract
ABSTRACT
The existence of airborne mycotoxins in mold-contaminated buildings has long been hypothesized to be a potential occupant health risk. However, little work has been done to demonstrate the presence of these compounds in such environments. The presence of airborne macrocyclic trichothecene mycotoxins in indoor environments with known
Stachybotrys chartarum
contamination was therefore investigated. In seven buildings, air was collected using a high-volume liquid impaction bioaerosol sampler (SpinCon PAS 450-10) under static or disturbed conditions. An additional building was sampled using an Andersen GPS-1 PUF sampler modified to separate and collect particulates smaller than conidia. Four control buildings (i.e., no detectable
S. chartarum
growth or history of water damage) and outdoor air were also tested. Samples were analyzed using a macrocyclic trichothecene-specific enzyme-linked immunosorbent assay (ELISA). ELISA specificity was tested using phosphate-buffered saline extracts of the fungal genera
Aspergillus
,
Chaetomium
,
Cladosporium
,
Fusarium
,
Memnoniella
,
Penicillium
,
Rhizopus
, and
Trichoderma
, five
Stachybotrys
strains, and the indoor air allergens Can f 1, Der p 1, and Fel d 1. For test buildings, the results showed that detectable toxin concentrations increased with the sampling time and short periods of air disturbance. Trichothecene values ranged from <10 to >1,300 pg/m
3
of sampled air. The control environments demonstrated statistically significantly (
P
< 0.001) lower levels of airborne trichothecenes. ELISA specificity experiments demonstrated a high specificity for the trichothecene-producing strain of
S. chartarum
. Our data indicate that airborne macrocyclic trichothecenes can exist in
Stachybotrys
-contaminated buildings, and this should be taken into consideration in future indoor air quality investigations.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference50 articles.
1. Bacteria, molds, and toxins in water-damaged building materials
2. Barnes, C., S. Buckley, F. Pacheco, and J. Portnoy. 2002. IgE-reactive proteins from Stachybotrys chartarum. Ann. Allergy Asthma Immunol.89:29-33.
3. Barnes, C., K. Schreiber, F. Pacheco, J. Landuyt, F. Hu, and J. Portnoy. 2000. Comparison of outdoor allergenic particles and allergen levels. Ann. Allergy Asthma Immunol.84:47-54.
4. Brasel, T. L., D. R. Douglas, S. C. Wilson, and D. C. Straus. 2004. Detection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins on particulates smaller than conidia. Appl. Environ. Microbiol.71:114-122.
5. Cage, B. R., K. Schreiber, C. Barnes, and J. Portnoy. 1996. Evaluation of four bioaerosol samplers in the outdoor environment. Ann. Allergy Asthma Immunol.77:401-406.
Cited by
102 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献