Improved detection of bacterial growth in continuous ambulatory peritoneal dialysis effluent by use of BacT/Alert FAN bottles

Author:

Alfa M J1,Degagne P1,Olson N1,Harding G K1

Affiliation:

1. Department of Medical Microbiology, University of Manitoba, Winnipeg, Canada. malfa@cc.umanitoba.ca

Abstract

Culture-negative peritonitis is a major complication for patients on continuous ambulatory peritoneal dialysis (CAPD) and precludes organism-specific therapy. The aim of the present study was to compare inoculation of 10 ml of CAPD effluent into BacT/Alert blood culture bottles (FAN [fastidious antimicrobic neutralizing], BacTAlert aerobic [BTA], and BacT/Alert anaerobic [BTAn] bottles) to our conventional method of using 50 ml of concentrated CAPD effluent to inoculate peptone broth bottles (BD bottles) and MacConkey agar and blood agar medium (BA-MAC). The FAN, BTA, and BTAn bottles were monitored automatically in the BacT/Alert blood culture instrument. A total of 207 CAPD effluents were studied, and in 97 bacteria were detected by at least one method. Compared to BTA bottles (79 of 97; 81.4%), BTAn bottles (78 of 97; 80.4%), and BD bottles (88 of 97; 90.7%), the single best broth medium for detecting bacterial growth in CAPD effluents was the FAN bottle (90 of 97 effluents; 92.8%). A total of 125 bacterial species were detected by any method, and the majority (91.8%) of CAPD effluents were infected with a single species. A combination of FAN and BTAn bottles detected 111 of 125 (88.8%) of all organisms, whereas a combination of BD bottles and BA-MAC detected 107 of 125 (85.6%) of all organisms. One or more organisms that would have been completely missed by the conventional method with BD bottles and BA-MAC were detected in 18 CAPD effluents. Of these 18 CAPD effluents, 6 showed no growth by the conventional method with BD bottles and BA-MAC. On the basis of our data, the most sensitive and least labor intensive method was direct inoculation of 10 ml of CAPD effluent into a FAN bottle and a BTAn bottle, which could be automatically monitored by the BacT/Alert blood culture instrument. On the basis of case definitions for peritonitis, the sensitivities and specificities of the methods with FAN and BTAn bottles and with BD bottles and BA-MAC were 81.1 and 98.8% and 74.5 and 96.5%, respectively.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference22 articles.

1. CAPD peritonitis: the Network 9;Bunke M.;Study. Adv. Peritoneal Dialysis,1994

2. Laboratory diagnosis of peritonitis in patients undergoing continuous ambulatory peritoneal dialysis;Fenton P.;J. Clin. Pathol.,1982

3. Evaluation of the Iysis-centrifugation system for culturing dialysates from continuous ambulatory peritoneal dialysis patients with peritonitis;Forbes B. A.;Am. J. Kidney Dis.,1988

4. Frequency of various types of peritoneal catheter infections and therapeutic outcome of treatment;Gucek A.;Adv. Peritoneal Dialysis,1995

5. Centrifugation of 50 ml of peritoneal effluent is sufficient for microbiological examination in continuous ambulatory peritoneal dialysis (CAPD) patients with peritonitis;Haechler H.;Infection,1986

Cited by 48 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Predictors of culture-negative peritoneal dialysis-associated peritonitis: a single center, retrospective study;Renal Replacement Therapy;2023-10-24

2. Comparison of BACTEC versus conventional enrichment medium for peritoneal dialysate fluid culture;Clinical Nephrology;2023-01-01

3. Peritoneal Infections in Peritoneal Dialysis (PD Peritonitis);Nolph and Gokal's Textbook of Peritoneal Dialysis;2023

4. Peritoneal Infections in Peritoneal Dialysis (PD Peritonitis);Nolph and Gokal's Textbook of Peritoneal Dialysis;2022-12-22

5. Reply to: ISPD 2022 recommendations for identification of causative organisms in peritonitis;Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis;2022-10-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3