Seven Human Immunodeficiency Virus (HIV) Antigen-Antibody Combination Assays: Evaluation of HIV Seroconversion Sensitivity and Subtype Detection

Author:

Ly Thoai Duong1,Martin Lynn2,Daghfal David2,Sandridge Arnold2,West Daniel2,Bristow Richard3,Chalouas Laurence1,Qiu Xiaoxing2,Lou Sheng C.2,Hunt Jeffrey C.2,Schochetman Gerald2,Devare Sushil G.2

Affiliation:

1. Laboratoire Claude Levy, Ivry sur Seine, France1;

2. Abbott Laboratories, Diagnostics Division, Abbott Park, Illinois2; and

3. Murex Biotech Ltd., Dartford, Kent, United Kingdom3

Abstract

ABSTRACT In this study, we evaluated the performance of two prototype human immunodeficiency virus (HIV) antigen-antibody (Ag-Ab) combination assays, one from Abbott Laboratories (AxSYM HIV Ag-Ab) and the other from bioMerieux (VIDAS HIV Duo Ultra), versus five combination assays commercially available in Europe. The assays were Enzygnost HIV Integral, Genscreen Plus HIV Ag-Ab, Murex HIV Ag-Ab Combination, VIDAS HIV Duo, and Vironostika HIV Uniform II Ag-Ab. All assays were evaluated for the ability to detect p24 antigen from HIV-1 groups M and O, antibody-positive plasma samples from HIV-1 groups M and O, HIV-2, and 19 HIV seroconversion panels. Results indicate that although all combination assays can detect antibodies to HIV-1, group M, subtypes A to G, circulating recombinant form (CRF) A/E, and HIV-1 group O, their sensitivity varied considerably when tested using diluted HIV-1 group O and HIV-2 antibody-positive samples. Among combination assays, the AxSYM, Murex, and VIDAS HIV Duo Ultra assays exhibited the best antigen sensitivity (at ∼25 pg of HIV Ag/ml) for detection of HIV-1 group M, subtypes A to G and CRF A/E, and HIV-1 group O isolates. However, the VIDAS HIV Duo Ultra assay had a lower sensitivity for HIV-1 group M and subtype C, and was unable to detect subtype C antigen even at 125 pg of HIV Ag/ml. The HIV antigen sensitivity of the VIDAS HIV Duo and Genscreen Plus combination assays was ∼125 pg of HIV Ag/ml for detection of all HIV-1 group M isolates except HIV-1 group O while the sensitivity of Vironostika HIV Uniform II Ag-Ab and Enzygnost HIV Integral Ag-Ab assays for all the group M subtypes was >125 pg of HIV Ag/ml. Among the combination assays, the AxSYM assay had the best performance for detection of early seroconversion samples, followed by the Murex and VIDAS HIV Duo Ultra assays.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3