Affiliation:
1. Vysis Inc., Downers Grove, Illinois 60515, USA.
Abstract
We present data from a clinical trial study in which an automated version (Galileo) of a previously described Q-Beta replicase-amplified probe assay (J. S. Shah et al., J. Clin. Microbiol. 33:1435-1441, 1995) was used for the direct detection of Mycobacterium tuberculosis complex in sputum. The assay was designed to target specific regions of 23S rRNA found in M. tuberculosis, Mycobacterium bovis, Mycobacterium africanum, and Mycobacterium microti and had a sensitivity ranging from approximately <10 to 300 CFU. The assay was tested for cross-hybridization by using large numbers (e.g., 10(5)to 10(10) CFU/assay) of 133 other organisms commonly found in respiratory tract samples, including non-M. tuberculosis Mycobacterium spp., other bacteria, fungi, and viruses. All of these competitors tested negative by the assay. Automated assay results for 780 respiratory tract samples (sputum or bronchoalveolar lavage specimens) collected and tested at three trial sites in the United States) were compared with the results of culture and acid-fast microscopy. Aliquots of conventionally digested and decontaminated sputum pellets were heated at 100 degrees C and mechanically disrupted prior to hybridization and background reduction, amplification, and detection in a closed disposable test pack. Pertinent elements of individual patient histories relating to tuberculosis exposure, previous active disease, antituberculosis therapy status, etc., were considered in the resolution of discrepant results for 48 (assay false-positive) samples. Seventy-one of 90 (78.9%) culture-positive samples were positive when tested in the Galileo assay, while 7% of culture-negative samples were assay positive, corresponding to a sensitivity of 79% and a specificity of 93%. Following resolution of discrepant results by chart review, the sensitivity and specificity for the Q-Beta replicase amplification assay with the Galileo analyzer were 84 and 97%, respectively. A total of 69.2% of smear-negative (culture positive) samples were detected by the assay. Ten test packs at a time were automatically processed by the Galileo analyzer without operator intervention following loading of samples. The first result was reported in approximately 3 h, and the last result was available in 6.5 h. To our knowledge, this is the first report of a clinical study with a fully automated amplification probe hybridization assay for the detection of pathogens directly from a clinical specimen.
Publisher
American Society for Microbiology
Reference52 articles.
1. Diagnostic standards and classification of tuberculosis;American Thoracic Society (Medical Section of the American Lung Association).;Am. Rev. Respir. Dis.,1990
2. Comparison of characteristics of Q~ replicase-amplified assay with competitive PCR assay for Chlamydia trachomatis;An Q.;J. Clin. Microbiol.,1995
3. Roche's Amplicor PCR test for tuberculosis should be used on smear-positive samples only, FDA panel stipulates in approvable recommendation;Anonymous;Med. Device Diagn. Instrument. Rep. (Gray Sheet),1996
4. Evaluation of Amplicor PCR for direct detection of Mycobacterium tuberculosis from sputum specimens;Beavis K. G.;J. Clin. Microbiol.,1995
5. Clinical evaluation of the Roche AMPLICOR PCR Mycobacterium tuberculosis test for detection of M. tuberculosis in respiratory specimens;Bergman J. S.;J. Clin. Microbiol.,1996
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献