Enhanced Enzyme Immunoassay with Negative-Gray-Zone Testing Compared to a Single Nucleic Acid Amplification Technique for Community-Based Chlamydial Screening of Men

Author:

Horner Paddy12,Skidmore Sue3,Herring Alan4,Sell Jo5,Paul Ian5,Caul Owen4,Egger Matthias6,McCarthy Anne6,Sanford Emma6,Salisbury Chris7,MacLeod John8,Sterne Jonathan6,Low Nicola6

Affiliation:

1. The Milne Centre, United Bristol Healthcare NHS Trust, Bristol BS2 8HW

2. Department of Pathology and Microbiology, University of Bristol, Bristol

3. Royal Shrewsbury Hospital Trust, Shrewsbury

4. Public Health Laboratory Service Bristol Laboratory, Bristol BS2 8EL

5. Health Protection Agency, Myrtle Road, Bristol BS2 8EL

6. Department of Social Medicine, University of Bristol, Bristol BS8 2PR

7. Division of Primary Care, University of Bristol, Bristol BS6 6JL

8. Department of Primary Care, University of Birmingham, Birmingham B15 2TT, United Kingdom

Abstract

ABSTRACT We evaluated a low-cost diagnostic strategy for detecting Chlamydia trachomatis in a low-prevalence population. We used an amplified enzyme immunoassay (EIA) with a reduced-cutoff “negative gray zone” to identify reactive specimens for confirmation by a nucleic acid amplification test. As part of the Chlamydia Screening Studies project, men provided a first-pass urine specimen, which they returned by post for testing. We tested 1,003 specimens by IDEIA PCE EIA (Dako) and Cobas PCR (Roche). There were 32 (3.2%) true positive specimens according to a combined standard using an algorithm requiring concordant results from at least two independent tests. All of these were positive by Cobas PCR and 24 were confirmed to be positive by PCE EIA, including 2 that gave results in the negative gray zone. There were 971 true negative specimens, 2 of which were positive by Cobas PCR and 19 of which were initially inhibitory for PCR. The relative sensitivity, specificity, positive predictive value, and negative predictive value of PCE EIA with PCR confirmation were 75.0% (95% confidence interval [CI], 56.6 to 88.5%), 100% (95% CI, 99.7 to 100%), 100% (95% CI, 88.3 to 100%), and 99.2% (95% CI, 98.4 to 99.6%), respectively. The corresponding values for Cobas PCR were 100% (95% CI, 89.1 to 100%), 99.8% (95% CI, 99.3 to 100%), 94.1% (95% CI, 76.9 to 98.2%), and 100% (95% CI, 99.6 to 100%), respectively, with 1.9% (19/1003) of the samples being initially indeterminate. When the prevalence of C. trachomatis is low, the use of an amplified EIA on urine specimens, with confirmation of results in the negative gray zone by use of a nucleic acid amplification technique, is not suitable for screening asymptomatic men. In addition, positive nucleic acid amplification test results should be confirmed and an inhibition control should be used.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3