Affiliation:
1. Jefferiss Trust Laboratories, Wright-Fleming Institute, Imperial College London
2. Research Department of Infection and Population Health, University College London
3. Department of Diagnostic Virology, St Mary's Hospital, Imperial College Healthcare NHS Trust
4. Health Protection Agency Centre for Infections, Colindale, London
5. Department of Social Medicine, University of Bristol
Abstract
ABSTRACT
Understanding of the burden of
Chlamydia trachomatis
infection and its clinical sequelae is hampered by the absence of accurate, well-characterized tests using serological methods to determine past exposure to infection. An “in-house” immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) based on the
C. trachomatis
-specific antigen Pgp3 was produced and evaluated against three commercial ELISAs derived from the major outer membrane protein: the Medac pELISA plus, the Savyon SeroCT-IgG ELISA, and the Ani Labsystems IgG enzyme immunoassay. Sensitivities and specificities were determined using sera from both male and female patients (
n
= 356) for whom
C. trachomatis
had been detected in the lower genital tract at least 1 month prior to the testing of the sample and from 722
Chlamydia
-negative children aged 2 to 13 years. The Pgp3 ELISA was significantly more sensitive (57.9% [95% confidence interval {95% CI}, 52.7 to 62.9%]) than the Ani Labsystems (49.2% [95% CI, 44.0 to 54.3%];
P
= 0.003), SeroCT (47.2% [95% CI, 42.1 to 52.4%];
P
< 0.0005), and Medac (44.4% [95% CI, 39.3 to 49.6%];
P
< 0.0005) ELISAs. The Pgp3, Ani Labsystems, and SeroCT assays, but not the Medac assay, had significantly higher sensitivity for female specimens than for male specimens (73.8 versus 44.2%, 59.8 versus 40.5%, 55.5 versus 40%, and 45.7 versus 43.7%, respectively). For female patients, the Pgp3 assay was 14.0% (95% CI, 5.5 to 22.5%) more sensitive than the next most sensitive ELISA, the Ani Labsystems assay (
P
= 0.001). There was no significant difference in specificity between the Pgp3 (97.6% [95% CI, 96.2 to 98.6%]), Ani Labsystems (99% [95% CI, 97.7 to 99.6%]), SeroCT (97.2% [95% CI, 95.7 to 98.2%]), and Medac (96% [95% CI, 94.3 to 97.2%]) ELISAs. None of the ELISAs showed evidence of cross-reactivity with antibodies to
Chlamydia pneumoniae
.
Publisher
American Society for Microbiology
Subject
Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy