Comparison of NucliSens and Amplicor Monitor Assays for Quantification of Human Immunodeficiency Virus Type 1 (HIV-1) RNA in Plasma of Persons with HIV-1 Subtype A Infection in Abidjan, Côte d’Ivoire

Author:

Nkengasong John N.1,Kalou Mirielle1,Maurice Chantal1,Bile Celestin1,Borget Marie-Yolande1,Koblavi Stéphania1,Boateng Emmanuel1,Sassan-Morokro Madeleine1,Anatole-Ehounou Ekpini1,Ghys Peter12,Greenberg Alan E.13,Wiktor Stefan Z.13

Affiliation:

1. Projet RETRO-CI, CHU Treichville, Abidjan, Côte d’Ivoire1;

2. Institute of Tropical Medicine, Antwerp, Belgium2

3. Division of HIV/AIDS Prevention, National Center for HIV, STD, and TB Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia3; and

Abstract

ABSTRACT We compared the sensitivity and accuracy of the NucliSens assay and those of both the standard and modified (addition of a new primer set, primer mix 1, supplied by Roche) Amplicor HIV Monitor assays to quantify human immunodeficiency virus type 1 (HIV-1) RNA in persons infected with HIV-1 subtype A in Abidjan, Côte d’Ivoire. Seventy-one plasma samples from HIV-1-seropositive persons at different stages of HIV infection and 15 samples from HIV antibody-negative persons were analyzed. The HIV-1 genetic subtype was determined either by DNA sequencing or by a restriction fragment length polymorphism assay. Of the 71 samples, 70 (98%) were subtype A and 1 was subtype G. Of the 70 subtype A samples, the proportion of RNA-positive plasma samples and mean HIV-1 RNA levels were significantly higher by the modified HIV Monitor assay ( n = 67 [96%]; mean RNA levels, 5.2 log 10 HIV-1 RNA copies/ml) than the NucliSens assay ( n = 56 [80%]; 4.3 log 10 HIV-1 RNA copies/ml) or the standard HIV Monitor assay ( n = 44 [63%]; mean RNA levels, 3.8 log 10 HIV-1 RNA copies/ml) (all P values were <0.05). The HIV-1 RNA levels by the modified HIV Monitor assay correlated significantly with those by the NucliSens assay ( r = 0.76; P < 0.001) and the standard HIV Monitor assay ( r = 0.57; P < 0.001), as did the RNA levels by the NucliSens and the standard HIV Monitor assays ( r = 0.60; P < 0.001). Lower CD4 cell counts were significantly correlated with higher HIV-1 RNA levels by all three assays ( r = −0.47 for the NucliSens assay, −0.45 for the standard HIV Monitor assay, and −0.62 for the modified HIV Monitor assay). These results indicate that the modified HIV Monitor assay has the highest sensitivity and efficiency at quantifying the levels of RNA in persons infected with HIV-1 subtype A and thus constitutes a valuable tool for the monitoring of RNA levels in areas of Africa were HIV-1 subtype A is predominant.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference13 articles.

1. Subtype-specific problems with quantification of plasma HIV-1 RNA;Alaeus A.;AIDS,1997

2. Clinical evaluation of branched DNA signal amplification for quantifying HIV type 1 in human plasma;Cao Y.;AIDS Res. Hum. Retroviruses,1995

3. Application of branched DNA signal amplification to monitor human immunodeficiency virus type 1 burden in human plasma;Dewar R.;J. Infect. Dis.,1994

4. Comparison of branched DNA and reverse transcriptase polymerase chain reaction for quantifying six different HIV-1 subtypes in plasma;Dunne A. L.;AIDS,1997

5. Ellenberger D. D. Pieniazek J. Nkengasong C.-C. Luo C. Maurice M. Janini A. Ramos D. Hu I.-M. Coulibaly E. Ekpini S. Z. Wiktor A. E. Greenberg G. Schochetman and M. Rayfield. Unpublished data.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3