Affiliation:
1. Scientific Divisions, Abbott Laboratories, North Chicago, Illinois 60064
Abstract
A micromethod for assaying serum levels of erythromycin is described. The assay had the following characteristics: detection of 0.03 to 0.035 μg/ml, a long-range curve which minimizes sample dilution, 0.04 ml for a single measurement (0.3 ml required for full coverage), and utility for a variety of body fluids. The method employs radial diffusion from small paper discs which were saturated by capillary action rather than by dipping or pipetting. Although the method was designed to handle serum in which the sample volume is limited, statistical analysis demonstrated that the method has satisfactory precision for routine use. A study of 10 consecutive assays indicates a precision of ±12% at the 95% confidence limits. The method of least squares was used to calculate the line of best fit, and the statistics were developed on this basis. The assay method is applicable to a variety of antibiotics.
Publisher
American Society for Microbiology
Subject
General Pharmacology, Toxicology and Pharmaceutics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine
Reference13 articles.
1. Levels of penicillin in serum of newborn infants;Abramowicz M.;Am. J. Diseases Children,1966
2. Simplified, accurate method for antibiotic assay of clinical specimens;Bennett J. V.;Appl. Microbiol.,1966
3. Brownlee K. A. 1960. Statistical theory and methodology in science and engineering. John Wiley & Sons Inc. New York p. 272-290.
4. The paper-disc agar-plate method for the assay of antibiotic substances;Beer E. J.;J. Bacteriol.,1945
5. Assay of antibiotics in small amounts of fluid;Ericsson H.;Scand. J. Clin. Lab. Invest.,1960
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献