We evaluated the abilities of the Vircell immunoglobulin G (IgG) and IgM indirect immunofluorescence assay (IFA) for
Legionella pneumophila
serogroup 1, the IgM and IgG enzyme-linked immunosorbent assay (ELISA) for
Legionella pneumophila
serogroup 1, and the IgM-plus-IgG ELISA for
Legionella pneumophila
serogroups 1 to 6 to diagnose Legionnaires' disease (LD) in a well-described sample of patients with and without LD. Also, we determined the agreements, sensitivities, and specificities of the different Vircell assays in comparison to a validated ELISA (Serion classic ELISA). Clinical sensitivity and specificity were 74.6% and 96.6%, respectively, for the IgM IFA, 65.1% and 88.0% for the IgG IFA, 92.3% and 100% for the IgM ELISA, 43.3% and 96.6% for the IgG ELISA, and 90.8% and 100% for the IgM-plus-IgG ELISA. Compared to Serion classic ELISA, agreement, sensitivity, and specificity were 80.0%, 83.1%, and 78.4%, respectively, for the IgM IFA, 75.2%, 66.0%, and 79.5% for the IgG IFA, 89.5%, 82.0%, and 97.6% for the IgM ELISA, 81.9%, 88.9%, and 78.0% for the IgG ELISA, and 93.5%, 90.0%, and 96.6% for the IgM-plus-IgG ELISA. The value of a positive diagnostic result obtained by the Vircell IgM IFA, the Vircell IgG IFA, and the Vircell IgG ELISA might not be acceptable for a diagnostic assay. Both the high specificities and sensitivities of the Vircell IgM ELISA and the IgM-plus-IgG ELISA and the high correlation with the Serion classic ELISA indicate that they are useful in the diagnosis of LD.
Publisher
American Society for Microbiology
Subject
Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy
Reference15 articles.
1. Boshuizen, H. C., J. W. Den Boer, H. de Melker, J. F. Schellekens, M. F. Peeters, J. A. van Vliet, and M. A. Conyn-van Spaendonck. 2003. Reference values for the SERION classic ELISA for detecting Legionella pneumophila antibodies. Eur. J. Clin. Microbiol. Infect. Dis.22:706-708.
2. Boshuizen, H. C., S. E. Neppelenbroek, H. van Vliet, J. F. Schellekens, J. W. Boer, M. F. Peeters, and M. A. Spaendonck. 2001. Subclinical Legionella infection in workers near the source of a large outbreak of Legionnaires' disease. J. Infect. Dis.184:515-518.
3. den Boer, J. W., and E. W. Yzerman. 2004. Diagnosis of Legionella infection in Legionnaires' disease. Eur. J. Clin. Microbiol. Infect. Dis.23:871-878.
4. de Ory, F., J. M. Echevarria, C. Pelaz, A. Tellez, M. A. Mateo, and J. Lopez. 2000. Detection of specific IgM antibody in the investigation of an outbreak of pneumonia due to Legionella pneumophila serogroup 1. Clin. Microbiol. Infect.6:64-68.
5. Legionella
and Legionnaires' Disease: 25 Years of Investigation
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献