Performance and reliability of the Enzygnost measles enzyme-linked immuno-sorbent assay for detection of measles virus-specific immunoglobulin M antibody during a large measles epidemic

Author:

Ozanne G1,d'Halewyn M A1

Affiliation:

1. Laboratoire de Santé Publique du Québec, Immunodiagnostic, Ste-Anne-de-Bellevue, Canada.

Abstract

Evaluation of the Enzygnost Measles Enzyme-Linked Immuno-Sorbent Assay kit (Behring) performance to detect specific immunoglobulin M (IgM) was carried out with 3,297 single serum samples and 898 paired serum samples collected during a measles epidemic (10,184 reported cases) in Quebec, Canada. Anti-measles IgM and IgG were detected by using the Enzygnost kit with the appropriate conjugates. Complement-fixing (CF) antibody (Ab) titers were assessed by the laboratory branch complement fixation micromethod. The Centers for Disease Control's clinical measles case definition was used. A modification of the manufacturer's optical density interpretation algorithm was introduced to allow for equivocal results, in addition to positive and negative ones. These three categories differed as to their association with a significant increase in CF Ab titer and the time between the onset of symptoms and phlebotomy. The IgM positivity rate for complement fixation-confirmed measles cases was 96.6% for vaccinated subjects and 100% for nonvaccinated subjects. The daily percentage of IgM seropositivity that was detected for subjects who became IgM positive within 30 days increased gradually from 40 to 90% for sera taken 1 to 7 days after the onset of symptoms, and it plateaued at 100% for sera taken 16 to 30 days after the onset of symptoms. IgM seropositivity was strongly associated with IgG seroconversion, CF Ab titer increase, and clinical measles (P less than 0.0001). Reproducibility was 100% for nonreactive sera and 99.1% for reactive sera. In conclusion, the Enzygnost Measles Enzyme-Linked Immuno-Sorbent Assay kit performed adequately to confirm measles virus infection during this epidemic. A second serum sample should be tested when an early-acute-phase serum sample is IgM negative.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference15 articles.

1. Measles active and passive immunity in a worldwide perspective;Black F. L.;Prog. Med. Virol.,1989

2. Measles in Canada;Canada Diseases Weekly Report;Can. Dis. Weekly Rep.,1990

3. Case definitions for public health surveillance;Centers for Disease Control.;Morbid. Mortal. Weekly Rep.,1990

4. Mild measles and secondary vaccine failure during a sustained outbreak in a highly vaccinated population;Edmonson M. B.;JAMA,1990

5. Evaluation of monoclonal antibody-based capture enzyme immunoassays for detection of specific antibodies to measles virus;Erdman D. D.;J. Clin. Microbiol.,1991

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3