Development, Validation, and Routine Application of a High-Performance Liquid Chromatography Method Coupled with a Single Mass Detector for Quantification of Itraconazole, Voriconazole, and Posaconazole in Human Plasma

Author:

Baietto Lorena1,D'Avolio Antonio1,Ventimiglia Giusi1,De Rosa Francesco Giuseppe1,Siccardi Marco1,Simiele Marco1,Sciandra Mauro1,Di Perri Giovanni1

Affiliation:

1. University of Turin, Department of Infectious Diseases, Turin, Italy

Abstract

ABSTRACT We have developed and validated a high-performance liquid chromatography method coupled with a mass detector to quantify itraconazole, voriconazole, and posaconazole using quinoxaline as the internal standard. The method involves protein precipitation with acetonitrile. Mean accuracy (percent deviation from the true value) and precision (relative standard deviation percentage) were less than 15%. Mean recovery was more than 80% for all drugs quantified. The lower limit of quantification was 0.031 μg/ml for itraconazole and posaconazole and 0.039 μg/ml for voriconazole. The calibration range tested was from 0.031 to 8 μg/ml for itraconazole and posaconazole and from 0.039 to 10 μg/ml for voriconazole.