Precision and Accuracy of a Procedure for Detecting Recent Human Immunodeficiency Virus Infections by Calculating the Antibody Avidity Index by an Automated Immunoassay-Based Method

Author:

Suligoi Barbara1,Galli Claudio2,Massi Mario3,Di Sora Fiorella4,Sciandra Mauro5,Pezzotti Patrizio1,Recchia Olga3,Montella Francesco4,Sinicco Alessandro5,Rezza Giovanni1

Affiliation:

1. Reparto AIDS e MST, Istituto Superiore di Sanità

2. Scientific Affairs, Abbott Diagnostics Division

3. Patologia Clinica

4. Clinic of Infectious Diseases, Ospedale S. Giovanni-Addolorata, Rome

5. Clinic of Infectious Diseases, Università di Torino, Turin, Italy

Abstract

ABSTRACT We evaluated the precision and accuracy of a procedure for detecting recent human immunodeficiency virus (HIV) infections, specifically, the avidity index (AI) calculated using a method based on an automated AxSYM HIV 1/2gO assay (Abbott). To evaluate precision, we performed multiple replicates on eight HIV-positive serum samples. To evaluate the accuracy in identifying recent infections (i.e., within 6 months of seroconversion), we used 216 serum samples from 47 persons whose dates of seroconversion were known. To evaluate the sensitivity and specificity of the procedure for different AI cutoff values, we performed receiver operating characteristic (ROC) analysis. To determine the effects of antiretroviral treatment, advanced stage of the disease (i.e., low CD4-cell count), and low HIV viral load on the AI, we analyzed 15 serum samples from 15 persons whose dates of seroconversion were unknown. The precision study showed that the procedure was robust (i.e., the total variance of the AI was lower than 10%). Regarding accuracy, the mean AI was significantly lower for samples collected within 6 months of seroconversion, compared to those collected afterwards (0.68 ± 0.16 versus 0.99 ± 0.10; P < 0.0001), with no overlap of the 95% confidence intervals. The ROC analysis revealed that an AI lower than 0.6 had a sensitivity of 33.3% and a specificity of 98.4%, compared to 87.9 and 86.3%, respectively, for an AI lower than 0.9. Antiretroviral treatment, low CD4-cell count, and low viral load had no apparent effect on the AI. In conclusion, this procedure is reproducible and accurate in identifying recent infections; it is automated, inexpensive, and easy to perform, and it provides a quantitative result with different levels of sensitivity and specificity depending on the selected cutoff.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3