Abstract
A total of 480 examination gloves (240 vinyl and 240 latex) were stressed by using manipulations designed to mimic patient care. At the highest use level, 38 (63%) of 60 vinyl gloves leaked bacteriophage phi X174 compared with 4 (7%) of 60 latex gloves. At lower use levels, there was no statistically significant difference in leakage.