Receiver Operating Characteristics Analyses of Food and Drug Administration-Cleared Serological Assays for Natural Rubber Latex-Specific Immunoglobulin E Antibody

Author:

Biagini Raymond E.1,Krieg Edward F.1,Pinkerton Lynne E.2,Hamilton Robert G.3

Affiliation:

1. Division of Applied Research and Technology1 and

2. Division of Surveillance Hazard Evaluations and Field Studies,2 National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Public Health Service, Department of Health and Human Services, Cincinnati, Ohio 45226, and

3. Division of Allergy and Clinical Immunology, Johns Hopkins Asthma and Allergy Center, Johns Hopkins University School of Medicine, Baltimore, Maryland 212243

Abstract

ABSTRACT Receiver operating characteristics (ROC) analyses to evaluate and compare the diagnostic accuracy of Food and Drug Administration (510K)-cleared natural rubber latex (NRL)-specific immunoglobulin E (IgE) antibody immunoassays have not been performed using well-characterized skin-testing reagents. Sera were collected from 311 subjects (131 latex puncture skin test [PST] positive and 180 PST negative). All masked, coded sera were analyzed for latex-specific IgE antibodies in the Diagnostic Products Corporation microplate AlaSTAT, HYCOR HY-TEC RAST, and Pharmacia-Upjohn CAP System RAST FEIA (CAP). Diagnostic accuracy was evaluated using GraphRoc for Windows software to construct and analyze ROC curves in relation to the subjects' PST status and the results of the immunoassays. The ROC areas under the curve (AUCs) ± standard error based on PST for the three diagnostic tests were 0.858 ± 0.024, 0.869 ± 0.024, and 0.924 ± 0.017, respectively, for AlaSTAT, CAP, and HY-TEC. The HY-TEC system had a significantly greater AUC based on PST than those observed for AlaSTAT ( P < 0.05) and CAP ( P < 0.05) analyses. When the diagnostic tests were probed as to the cutoffs giving maximal diagnostic efficiency compared to PST, CAP and AlaSTAT yielded values of <0.35 kU of allergen IgE (kU A )/liter and <0.35 kU/liter while the HY-TEC assay yielded 0.11 kU/liter. The diagnostic efficiencies based on PST in our cohort at these cutoffs were 87.1, 88.1, and 88.7%, respectively. The HY-TEC assay had a significantly greater AUC than CAP and AlaSTAT using PST as a diagnostic discriminator in our cohort. When the HY-TEC system was probed at its maximally efficient cutoff (0.11 kU/liter) versus HYCOR's recommended cutoff of 0.05 kU/liter, a loss of sensitivity of 8.4% was observed with a gain in specificity of 19.5%.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

Reference21 articles.

1. Prevalence of latex sensitization among hospital physicians occupationally exposed to latex gloves.;Arellano R.;Anesthesiology,1992

2. Biases in the assessment of diagnostic tests.;Begg C. B.;Stat. Med.,1987

3. Latex glove allergy: a survey of the US Army Dental Corps.;Berky Z. T.;JAMA,1992

4. Natural rubber latex-specific IgE antibodies in non-healthcare workers: comparison of two FDA-cleared in vitro kits.;Biagini R. E.;J. Environ. Med.,1999

5. Galen R. S. Peters T. Jr. Analytical goals and clinical relevance of laboratory procedures Textbook of clinical chemistry. W. B. Tietz N. W. 1986 394 398 Saunders Company Philadelphia Pa