Devices for Rapid Diagnosis of Malaria: Evaluation of Prototype Assays That Detect Plasmodium falciparum Histidine-Rich Protein 2 and a Plasmodium vivax -Specific Antigen

Author:

Forney J. Russ1,Wongsrichanalai Chansuda2,Magill Alan J.3,Craig Leslie G.1,Sirichaisinthop Jeeraphat4,Bautista Christian T.3,Miller R. Scott5,Ockenhouse Christian F.6,Kester Kent E.6,Aronson Naomi E.5,Andersen Ellen M.3,Quino-Ascurra Higinio A.7,Vidal Carlos7,Moran Kimberly A.5,Murray Clinton K.8,DeWitt Caroline Cady9,Heppner D. Gray6,Kain Kevin C.10,Ballou W. Ripley6,Gasser Robert A.6

Affiliation:

1. United States Military Academy, West Point, New York

2. Armed Forces Research Institute of Medical Sciences, Bangkok

3. Naval Medical Research Center Detachment, Lima

4. Vector Born Disease Control Office 1, Phrabuddhabat, Saraburi, Thailand

5. Walter Reed Army Medical Center, Washington, D.C.

6. Walter Reed Army Institute of Research, Silver Spring, Maryland

7. Hospital de Apoyo, Iquitos, Peru

8. Brooke Army Medical Center, San Antonio

9. Wilford Hall Medical Center, Lackland Air Force Base, Texas

10. The Toronto General Hospital and University of Toronto, Toronto, Ontario, Canada

Abstract

ABSTRACT The Para Sight F test was developed as a pioneer industry effort in the large-scale, process-controlled production of a device for the rapid diagnosis of malaria. This device performed well in field settings but was limited to the detection of a single malaria species, Plasmodium falciparum. The Para Sight F+V assay advanced upon the Para Sight F test format by incorporating a monoclonal antibody directed against a proprietary Plasmodium vivax -specific antigen, in addition to the antibody directed against P. falciparum histidine-rich protein 2, which was used in the Para Sight F assay. The modified assay was developed to add the capability to detect P. falciparum and P. vivax in a single-test-strip format. The present study evaluated three distinct Para Sight F+V prototypes with samples from symptomatic patients in regions of Thailand and Peru where malaria is endemic. Over a 2-year enrollment period (1998 and 1999), a total of 4,894 patients consented to participation in the study. Compared with the results for duplicate microscopic examinations of Giemsa-stained blood smears as the reference diagnostic standard, each successive prototype showed substantial improvement in performance. The final Para Sight F+V prototype, evaluated in 1999, had an overall sensitivity for detection of asexual P. falciparum parasites of 98%. The sensitivity of the device was 100% for P. falciparum densities of >500 parasites/μl, with a sensitivity of 83% for parasite densities of ≤500/μl. The specificity for the exclusion of P. falciparum was 93%. For P. vivax , the overall sensitivity was 87% for the final 1999 prototype. The sensitivities calculated for different levels of P. vivax parasitemia were 99% for parasite densities of >5,000/μl, 92% for parasite densities of 1,001 to 5,000/μl, 94% for parasite densities of 501 to 1,000/μl, and 55% for parasite densities of 1 to 500/μl. The specificity for the exclusion of P. vivax was 87%. The areas under the receiver operating characteristic curves for the diagnostic performance of the assay for the detection of P. falciparum and P. vivax were 0.8907 and 0.8522, respectively. These findings indicate that assays for rapid diagnosis have the potential to enhance diagnostic capabilities in those instances in which skilled microscopy is not readily available.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3