Use of the Bac-T-Screen to predict bacteriuria from urine specimens held at room temperature

Author:

Wright D N,Saxon B,Matsen J M

Abstract

Results from the Bac-T-Screen (BTS) of fresh urine specimens were compared with the BTS results obtained when the same urine specimens had been held at room temperature for 24 h. Of the 246 specimens studied, 43 were initially BTS positive, 11 were false-negative, and 39 had greater than or equal to 10(5) CFU/ml. After 24 h at room temperature an additional 60 specimens had greater than or equal to 10(5) CFU/ml, of which only 16 were BTS positive; 10 specimens still gave false-negative results, and the number of false-positive specimens increased by only 6.5% of all specimens. For significant specimens (containing greater than or equal to 10(5) CFU of probable pathogens per ml), the predictive value of a negative test changed by only 0.1% (99.5 to 99.4%), whereas the sensitivity of the test remained at 96.4% for incubated specimens. Of those specimens that developed greater than or equal to 10(5) CFU/ml in vitro, 85% contained gram-negative bacilli. Neither bacteria grown in vitro nor urine specimens from normal females containing greater than or equal to 10(5) CFU/ml were positive with the BTS. For reasons not entirely understood, the BTS system may be unique in its ability to discriminate between bacteria which represent true bacteriuria and those which are present because of contamination, possibly due to other cellular elements present in infection-related bacteriuria, namely leukocytes and sloughed bladder epithelial cells.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference17 articles.

1. Barry A. L. P. B. Smith and M. Turck. 1975. Cumitech 2 Laboratory diagnosis of urinary tract infections. Coordinating ed. T. L. Gavan. American Society for Microbiology Washington D.C.

2. Galen R. S. and S. R. Gambino. 1975. Beyond normality: the predictive value and efficiency of medical diagnosis. John Wiley & Sons Inc. New York.

3. Evaluation of the B-D urine culture kit;Guenther K. L.;J. Clin. Microbiol.,1981

4. Use of semiquantitative microscopic method for detecting bacteriuria;Hashimoto F. W.;Arch. Intern. Med.,1980

5. Rapid semiautomated screening and processing of urine specimens;Jenkins R. D.;J. Clin. Microbiol.,1980

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献