ABSTRACT
Previous studies have reported that galactomannan (GM) enzyme immunoassay and 1,3 beta-glucan (BG) assay may be useful diagnostic tools, but their sensitivities are variable. We compared the performances of both tests. Between October 2002 and May 2005, 82 patients were prospectively monitored for 12 weeks. A total of 414 samples were tested by GM assay and 409 samples were tested by BG assay for the following four groups of patients: those with invasive aspergillosis (IA), those with other mold infections (
Fusarium
, scedosporium, zygomycosis, etc.), those with candidemia, and control patients. Blood samples were obtained twice on week 1 and once every other week for a total of 12 weeks. Patients in the invasive fungal infection groups had comparable risk factors. The sensitivity of the GM test was significantly higher for patients with IA due to non-
fumigatus Aspergillus
species than for patients with IA due to
Aspergillus fumigatus
(49% versus 13%;
P
< 0.0001) or with other mold infections (49% versus 6%;
P
< 0.0001). However, the sensitivity range (47% to 64%) and specificity (88%) of the BG assay were comparable among all patients tested, regardless of the infecting pathogen. The performance of GM-based diagnosis appears to be better for detecting non-
fumigatus Aspergillus
species. The diagnostic marker BG was shown to have a higher sensitivity than that of GM in detecting IA and other mold infections in hematologic malignancy patients.