Volume of blood submitted for culture from neonates

Author:

Neal P R,Kleiman M B,Reynolds J K,Allen S D,Lemons J A,Yu P L

Abstract

We prospectively examined 298 sets (298 aerobic, 299 anaerobic, and 73 resin cultures) of blood cultures from 161 critically ill newborns. The attending physicians were unaware of the study. The mean blood volume per patient (aerobic and anaerobic) was 1.05 (range, 0.11 to 3.04) ml. The mean blood volume per aerobic bottle was 0.53 (range, 0.01 to 1.90) ml. Among aerobic samples 2.7% were less than or equal to 0.1 ml, 16% were less than or equal to 0.3 ml, 33% were less than or equal to 0.4 ml, and 55% were less than or equal to 0.5 ml. For anaerobic cultures the mean blood volume was 0.52 (range, 0.01 to 1.79) ml. Among anaerobic samples 2.7% were less than or equal to 0.1 ml, 15% were less than or equal to 0.3 ml, 35% were less than or equal to 0.4 ml, and 58% were less than or equal to 0.5 ml. Blood volume did not correlate with gestational age, chronologic age, or weight. The mean volume of blood submitted in positive cultures was not significantly greater than that in negative cultures. The blood volume used for culture from ill newborns may be inadequate for detecting sepsis, and the adequacy of currently available culture methods needs to be assessed for the small samples submitted from critically ill newborns.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference11 articles.

1. Rapid detection of bacteremia in children with a modified Iysis direct plating method;Campos J. M.;J. Clin. Microbiol.,1985

2. Clinical comparison of the isolator 1.5 microbial tube the the BACTEC radiometric system for detection of bacteremia in children;Carey R. B.;J. Clin. Microbiol.,1984

3. Neonatal Escherichia coli speticemia-bacterial counts in blood;Dietzman D. E.;J. Pediatr.,1974

4. Effect of volume of blood cultured on detection of bacteremia;Hall M. M.;J. Clin. Microbiol.,1976

5. Isenberg H. D. J. A. Washington II A. Balows and A. C. Sonnenwirth. 1980. Collection handling and processing of specimens p. 52-82. In E. H. Lennette A. Balows W. J. Hausler Jr. and J. P. Truant (ed.) Manual of clinical microbiology 3rd ed. American Society for Microbiology Washington D.C.

Cited by 76 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3