Serologic Testing for Trypanosoma cruzi : Comparison of Radioimmunoprecipitation Assay with Commercially Available Indirect Immunofluorescence Assay, Indirect Hemagglutination Assay, and Enzyme-Linked Immunosorbent Assay Kits

Author:

Leiby David A.1,Wendel Silvano2,Takaoka Deise T.2,Fachini Roberta M.2,Oliveira Lea C.2,Tibbals Melinda A.1

Affiliation:

1. Transmissible Diseases Department, American Red Cross, Rockville, Maryland,1 and

2. Hospital Sı́rio Libanês, São Paulo, Brazil2

Abstract

ABSTRACT The radioimmunoprecipitation assay (RIPA) has been used as a confirmatory test in several ongoing and published studies of Trypanosoma cruzi in blood donors in the United States. Despite its use as a confirmatory test, few studies are available comparing RIPA to commercially available serologic test methods. Thus, we compared RIPA with two indirect hemagglutination assays (Biolab Diagnostica SA, São Paulo, Brazil; Hemagen Diagnostics, Inc., Waltham, Mass.) and four different enzyme-linked immunosorbent assays (Abbott Laboratories, Abbott Park, Ill.; Embrabio, São Paulo, Brazil; Organon Teknika, São Paulo, Brazil; and Gull Laboratories, Salt Lake City, Utah) using a panel of 220 serum specimens from Brazilian blood donors with a range of T. cruzi antibody titers as determined by indirect immunofluorescence assay (IFA). A titer of 1:20 was used as the baseline for seropositivity. All IFA-negative serum specimens ( n = 19) were nonreactive on all tests. At a titer of 1:20 ( n = 9), reactivity rates varied considerably among the tests, with only the RIPA and the Organon and Gull assays identifying reactive specimens. For specimens at a 1:40 titer ( n = 35), most assays identified at least 32 of 35 (91%) specimens as reactive, but the Biolab assay only identified 24 (69%). At higher titers (1:80, n = 56; 1:160, n = 101) the assays were comparable, with the exception of the Biolab assay, demonstrating rates of agreement with IFA of ≥98%. Overall, when compared with several other test formats, RIPA demonstrated equivalent or superior rates of agreement with IFA-positive specimens across all titers examined. In particular, at titers of >1:40, the RIPA compared favorably with other test methods currently in use, supporting its application as a confirmatory test, particularly in a research setting.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 71 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3