Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek AutoMicrobic system for identification of gram-negative bacilli

Author:

Robinson A1,McCarter Y S1,Tetreault J1

Affiliation:

1. Department of Pathology and Laboratory Medicine, Hartford Hospital, Connecticut 06102-5037.

Abstract

A comparative evaluation of the Crystal Enteric/Nonfermenter system (Crystal; Becton Dickinson, Cockeysville, Md.), API 20E (API; bioMérieux Vitek, Inc., Hazelwood, Mo.), and the Vitek GNI card (Vitek; bioMérieux Vitek) was performed with 512 clinical isolates of gram-negative bacilli, including 381 members of the family Enterobacteriaceae and 131 nonenteric bacilli. With supplemental testing, API, Crystal, and Vitek correctly identified to the genus and species level 505 (98.6%), 489 (95.5%), and 494 (96.5%) of the 512 isolates, respectively. Supplemental testing, as specified by the manufacturer, was required to identify 119 (23.2%), 18 (3.5%), and 5 (1.0%) of the isolates with the three systems, respectively. Of the 381 isolates from the family Enterobacteriaceae, API and Crystal correctly identified 90.3 and 91.6% by 18 to 24 h without supplemental testing, respectively, and Vitek identified 92.4 and 96.1% following 10 and 18 h of incubation, respectively. Of the 131 nonenteric organisms, API and Crystal correctly identified 28.2 and 93.9% by 18 to 24 h without supplemental testing, respectively, and Vitek identified 84.0% by 10 h and 93.9% by 18 h. Errors in identification with each system were infrequent and appeared to be randomly distributed among the genera evaluated. The three systems were comparable in accuracy when either a weighted clinical laboratory profile of organisms or a group of selected isolates in a stress test sample was evaluated (P > 0.05). There were no significant differences between the three systems in their ability to identify either the isolates in the weighted group or those in the stress test (P > 0.05). Crystal compared favorably with API and Vitek, which have established track records in clinical laboratories, and is acceptable for the identification of members of the Enterobacteriaceae and nonenteric bacilli in a clinical microbiology laboratory.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference24 articles.

1. Correlation studies of Entero-Set 20, API 20E, and conventional media systems for Enterobacteriaceae identification;Aldridge K. E.;J. Clin. Microbiol.,1981

2. Use of the Autobac IDX system for rapid identification of Enterobacteriaceae and nonfermentative gram-negative bacilli;Costigan W. J.;J. Clin. Microbiol.,1984

3. D'Amato R. F. E. J. Bottone and D. Amsterdam. 1991. Substrate profile systems for the identification of bacteria and yeasts by rapid and automated approaches p. 128-136. In A. Balows W. J. Hausler Jr. K. L. Herrmann H. D. Isenberg and H. J. Shadomy (ed.) Manual of clinical microbiology 5th ed. American Society for Microbiology Washington D.C.

4. Ewing W. H. 1986. Edward's and Ewing's identification of Enterobacteriaceae 4th ed. Elsevier Science Publishing Co. Inc. New York.

5. Evaluation of two BBL Crystal systems for identification of some clinically important gramnegative bacteria;Holmes B.;J. Clin. Microbiol.,1994

Cited by 43 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3