Evaluation of the Merlin MICRONAUT System for Rapid Direct Susceptibility Testing of Gram-Positive Cocci and Gram-Negative Bacilli from Positive Blood Cultures

Author:

Wellinghausen Nele1,Pietzcker Tim1,Poppert Sven1,Belak Syron1,Fieser Nicole1,Bartel Melanie1,Essig Andreas1

Affiliation:

1. Institute of Medical Microbiology and Hygiene, University Hospital of Ulm, Ulm, Germany

Abstract

ABSTRACT Bloodstream infections are life-threatening conditions which require the timely initiation of appropriate antimicrobial therapy. We evaluated the automated Merlin MICRONAUT system for rapid direct microtiter broth antimicrobial susceptibility testing (AST) of gram-positive cocci and gram-negative bacilli from BACTEC 9240 bottles with positive blood cultures in comparison to the standard method for the Merlin MICRONAUT system. This prospective study was conducted under routine working conditions during a 9-month period. Altogether, 504 isolates from 409 patients and 11,819 organism-antibiotic combinations were evaluated for comparison of direct and standard AST methods. For gram-negative bacilli, direct and standard AST of 110 isolates was evaluated and MIC agreement was found for 98.1% of 2,637 organism-antibiotic combinations. Category (susceptible, intermediate susceptible, resistant [SIR]) agreement was found for 99.0%, with results for 0.04% of combinations showing very major errors, those for 0.2% showing major errors, and those for 0.8% showing minor errors. For gram-positive cocci, 373 isolates were evaluated and MIC agreement was found for 95.6% of 8,951 organism-antibiotic combinations. SIR agreement was found for 98.8%, with results for 0.3% of combinations showing very major errors, those for 0.4% showing major errors, and those for 0.5% showing minor errors. Although the number of tested isolates was limited ( n = 33), direct AST of streptococci was performed for the first time, yielding promising results with SIR agreement for 98.6% of 363 organism-antibiotic combinations. In conclusion, direct AST of gram-negative bacilli and gram-positive cocci from positive blood cultures with the MICRONAUT system is a reliable technique that allows for the omission of repeat testing of subcultured isolates. Thereby, it reduces the time to results of blood culture testing and may have a positive impact on patient care.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3