Affiliation:
1. Department of Medical Microbiology, University of Amsterdam, The Netherlands.
Abstract
In the study that is described the sensitivities and specificities of three commercial tests and the standard Reference Laboratory test, used since 1961, to identify Neisseria meningitidis serogroups were compared. The tests marketed by Difco, Murex/Wellcome, and Sanofi/Pasteur showed overall sensitivities of 92, 95, and 100%, respectively, and specificities of 67, 88, and 82%, respectively. When limited to the common serogroups A, B, and C, the three tests yielded sensitivities of 93, 97, and 100%, respectively, and specificities of 98, 100, and 98%, respectively. However, determination of the uncommon serogroups X, W-135, Y, Z, and 29E with these tests is either unreliable or not possible.
Publisher
American Society for Microbiology
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献