Affiliation:
1. Center for Interfacial Microbial Process Engineering, Montana State University, Bozeman 59717.
Abstract
The growth of environmental and clinical coliform bacteria under conditions typical of drinking water distribution systems was examined. Four coliforms (Klebsiella pneumoniae, Escherichia coli, Enterobacter aerogenes, and Enterobacter cloacae) were isolated from an operating drinking water system for study; an enterotoxigenic E. coli strain and clinical isolates of K. pneumoniae and E. coli were also used. All but one of the coliforms tested were capable of growth in unsupplemented mineral salts medium; the environmental isolates had greater specific growth rates than did the clinical isolates. This trend was maintained when the organisms were grown with low levels (less than 1 mg liter-1) of yeast extract. The environmental K. pneumoniae isolate had a greater yield, higher specific growth rates, and a lower Ks value than the other organisms. The environmental E. coli and the enterotoxigenic E. coli strains had comparable yield, growth rate, and Ks values to those of the environmental K. pneumoniae strain, and all three showed significantly more successful growth than the clinical isolates. The environmental coliforms also grew well at low temperatures on low concentrations of yeast extract. Unsupplemented distribution water from the collaborating utility supported the growth of the environmental isolates. Growth of the K. pneumoniae water isolate was stimulated by the addition of autoclaved biofilm but not by tubercle material. These findings indicate that growth of environmental coliforms is possible under the conditions found in operating municipal drinking water systems and that these bacteria could be used in tests to determine assimilable organic carbon in potable water.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference18 articles.
1. Allen M. J. and E. E. Geldreich. 1977. Distribution line sediments and bacterial regrowth p. 1-8. In American Water Works Association Water Quality Technology Conference Philadelphia. American Water Works Research Foundation Denver.
2. Biological processes in drinking water;Bouwer E. J.;J. Am. Water Works Assoc.,1988
3. Detection of elevated levels of coliform bacteria in a public water supply;Centers for Disease Control.;Morbid. Mortal. Weekly Rep.,1985
4. Growth and comparative physiology of Klebsiella oxytoca attached to GAC in liquid media;Davies D. G.;Microb. Ecol.,1988
5. Phenotypic characteristics of coliform and noncoliform bacteria from a public water supply compared with regional and national clinical species;Edberg S. C.;Appl. Environ. Microbiol.,1986
Cited by
87 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献