Quantitative detection of human immunodeficiency virus (HIV) antigen by the Enzymun-Test: comparison with alternative assays and nucleic acid sequence-based amplification of HIV type 1 RNA

Author:

Weber B1,Melchior W1,Preiser W1,Hess G1,Wahl M1,Braner J1,Doerr H W1

Affiliation:

1. Institut für Medizinische Virologie, Zentrum der Hygiene, Universitätskliniken Frankfurt am Main, Germany.

Abstract

A new modular automated enzyme immunoassay (EIA) (Enzymun-Test HIV Ag: Boehringer Mannheim) for quantitative human immunodeficiency virus (HIV) antigen detection was evaluated by testing a panel of 1,506 serum samples, including seroconversions, dilution series, follow-up samples from patients under antiretroviral therapy, single serum specimens from HIV-seropositive individuals in different stages of infection, potentially cross-reactive samples, and sera from HIV-negative hospitalized patients. The Abbott HIV type 1 (HIV-1) antigen monoclonal antibody assay served as the reference assay, and nucleic acid sequence-based amplification (Organon Teknika) for quantitative amplification of HIV-1 RNA was used for follow-up of patients under antiretroviral chemotherapy. The Boehringer Mannheim and Abbott EIAs showed concordant results for the early detection of HIV antigen in all the seroconversion panels. The follow-up samples from 29 HIV-infected individuals under antiretroviral therapy gave divergent results between both antigen tests. For the detection of HIV antigen in single serum samples from HIV-infected patients in different stages of HIV infection, a higher number of positive samples was detected with the Abbott HIV-1 antigen monoclonal antibody assay in samples from patients in stages II and III of HIV infection. The Enzymun-Test detected three or more positive samples than did the Abbott assay among the samples of patients with AIDS. The concordance on a sample-to-sample basis between the Boehringer Mannheim and Abbott EIAs was 98.6%. The sensitivity of the Enzymun-Test in comparison to the reference assay was 97.2%; the specificity was 98.8%. Although no close correlation could be found between the amount of viral RNA in serum detected by nucleic acid sequence-based amplification and the concentration of HIV antigen, a high HIV-1 RNA copy number was mostly associated with high levels of HIV antigen. In conclusion, the Enzymun-Test permits accurate HIV antigen detection and offers, in contrast to previous assays, the possibility of completely automated detection.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3