Comparison of Serologic Assays and PCR for Diagnosis of Human Herpesvirus 8 Infection

Author:

Spira Thomas J.1,Lam Lee1,Dollard Sheila C.2,Meng Yuan-Xiang2,Pau Chou Pong1,Black Jodi B.2,Burns Darrell2,Cooper Brian1,Hamid Melissa2,Huong Joe2,Kite-Powell Kathleen2,Pellett Philip E.2

Affiliation:

1. Immunology Branch, Division of AIDS, STD, and TB Laboratory Research,1 and

2. Viral Exanthems and Herpesvirus Branch, Division of Viral and Rickettsial Diseases,2 National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia

Abstract

ABSTRACT A variety of assays for the diagnosis human herpesvirus 8 (HHV-8) infection have been reported. We compared several such assays with a panel of 88 specimens from human immunodeficiency virus (HIV)-infected patients with Kaposi's sarcoma (KS) (current-KS patients; n = 30), HIV-infected patients who later developed KS (later-KS patients; n = 13), HIV-infected patients without KS (no-KS patients; n = 25), and healthy blood donors ( n = 20). PCR assays were also performed with purified peripheral blood mononuclear cells (PBMCs) to confirm positive serologic test results. The order of sensitivity of the serologic assays (most to least) in detecting HHV-8 infection in current-KS patients was the mouse monoclonal antibody-enhanced immunofluorescence assay (MIFA) for lytic antigen (97%), the orfK8.1 peptide enzyme immunoassay (EIA) (87%), the orf65 peptide EIA (87%), MIFA for latent antigen (83%), the Advanced Biotechnologies, Inc., EIA (80%), and the orf65 immunoblot assay (80%). Combination of the results of the two peptide EIAs (combined peptide EIAs) increased the sensitivity to 93%. For detection of infection in later-KS patients, the MIFA for lytic antigen (100%), the orfK8.1 peptide EIA (85%), and combined peptide EIAs (92%) were the most sensitive. Smaller percentages of no-KS patients were found to be positive (16 to 56%). Most positive specimens from the current-KS and later-KS groups were positive by multiple assays, while positive specimens from the no-KS group tended to be positive only by a single assay. PCR with PBMCs for portions of the HHV-8 orf65 and gB genes were positive for less than half of current-KS and later-KS patients and even fewer of the no-KS patients. The concordance between serologic assays was high. We propose screening by the combined peptide EIAs. For specimens that test weakly positive, we recommend that MIFA for lytic antigen be done. A positive result with a titer of ≥1:40 would be called HHV-8 positive. A negative or low titer would be called HHV-8 negative. If a population has a high percentage of persons who test positive by the combined peptide EIAs, then a MIFA could be performed with the negative specimens to determine if any positive specimens are being missed. Alternatively, if a population has a low percentage that test positive, then a MIFA could be performed with a subset of the negative specimens for the same reason. As described above, only a titer of ≥1:40 would be considered HHV-8 positive.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司