Affiliation:
1. Pandex Division, Baxter Diagnostics, Mundelein, Illinois 60060.
Abstract
Tests for the detection of antibodies to Treponema pallidum are recommended for the confirmation of reactive nontreponemal test results and the accurate diagnosis of syphilis. The present-day use of Western blot (immunoblot) technology for the diagnosis of retroviruses prompted the development and evaluation of a Western blot assay with whole-cell T. pallidum as the antigen. The assay detected antibodies in syphilitic serum or plasma from dilutions of specimens incubated overnight with test strips. A test was considered positive when at least three of four major antigens having molecular masses of 15.5, 17, 44.5, and 47 kDa were detected. The Western blot assay had 93.8% sensitivity and 100% specificity for clinically defined samples. The Western blot assay was compared with double-staining fluorescent treponemal antibody absorption [FTA-ABS (DS)], which had a sensitivity and a specificity of 91.7 and 92.0%, respectively. Dilution series studies of syphilis-positive specimens indicated that the Western blot assay has an endpoint of reactivity at least 3 to 4 serial dilutions greater than that for FTA-ABS (DS). Overall, the greater than 95% agreement between the Western blot assay and FTA-ABS (DS) for clinically defined specimens indicates that the sensitivity of the Western blot assay is equal to or greater than that of FTA-ABS (DS). The Western blot assay demonstrated no false-positive or equivocal reactivities for nonsyphilitic specimens, including normal specimens (both plasma and serum), biological false-positives, and specimens with elevated gamma globulin or antinuclear antibody. We conclude that the high sensitivity and specificity of the T. pallidum Western blot assay, together with its simplicity and objectivity, make it a good confirmatory test for syphilis.
Publisher
American Society for Microbiology
Reference23 articles.
1. A rapid, sensitive method for detection of alkaline phosphatase-conjugated anti-antibody on Western blots;Blake M. S.;Anal. Biochem.,1984
2. FTA-ABS test in pregnancy: a probable false-positive reaction;Buchanon C.;Arch. Dermatol.,1970
3. Center for Disease Control. 1977. Maintenance of Treponema palliduin (Nichols strain) in rabbits. Center for Disease Control Atlanta.
4. Hausser-Scientific Partnership. 1972. Form DU90. Directions for use of Petroff-Hausser and Helber chambers. Hausser Scientific Horsham Pa.
5. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis immunoblotting as a serological tool in the diagnosis of syphilitic infections;Hensel U.;J. Clin. Microbiol.,1985
Cited by
46 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献