Affiliation:
1. Biochip Technology Center, Argonne National Laboratory, Argonne, Illinois 60439
2. Environmental Microbiology Group, Pacific Northwest National Laboratory, Richland, Washington 99352
Abstract
ABSTRACT
Autonomous, field-deployable molecular detection systems require seamless integration of complex biochemical solutions and physical or mechanical processing steps. In an attempt to simplify the fluidic requirements for integrated biodetection systems, we used tunable surface microparticles both as an rRNA affinity purification resin in a renewable microcolumn sample preparation system and as the sensor surface in a flow cytometer detector. The tunable surface detection limits in both low- and high-salt buffers were 1 ng of total RNA (∼10
4
cell equivalents) in 15-min test tube hybridizations and 10 ng of total RNA (∼10
5
cell equivalents) in hybridizations with the automated system (30-s contact time). RNA fragmentation was essential for achieving tunable surface suspension array specificity. Chaperone probes reduced but did not completely eliminate cross-hybridization, even with probes sharing <50% identity to target sequences. Nonpurified environmental extracts did not irreparably affect our ability to classify color-coded microparticles, but residual environmental constituents significantly quenched the Alexa-532 reporter fluor. Modulating surface charge did not influence the interaction of soluble environmental contaminants with conjugated beads. The automated system greatly reduced the effects of fluorescence quenching, especially in the soil background. The automated system was as efficacious as manual methods for simultaneous sample purification, hybridization, and washing prior to flow cytometry detection. The implications of unexpected target cross-hybridization and fluorescence quenching are discussed relative to the design and implementation of an integrated microbial monitoring system.
Publisher
American Society for Microbiology
Subject
Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology
Reference30 articles.
1. The oligonucleotide probe database
2. Ausubel F. M. R. Brent R. E. Kingston D. D. Moore J. G. Seidman J. A. Smith and K. Struhl (ed.). 1995. Current protocols in molecular biology. John Wiley & Sons Inc. New York N.Y.
3. Portable System for Microbial Sample Preparation and Oligonucleotide Microarray Analysis
4. Belgrader, P., W. Bennett, D. Hadley, G. Long, R. Mariella, Jr., F. Milanovich, S. Nasarabadi, W. Nelson, J. Richards, and P. Stratton. 1998. Rapid pathogen detection using a microchip PCR array instrument. Clin. Chem.44:2191-2194.
5. Belosludtsev, Y., I. Belosludtsev, B. Iverson, S. Lemeshko, R. Wiese, M. Hogan, and T. Powdrill. 2001. Nearly instantaneous, cation-independent, high selectivity nucleic acid hybridization to DNA microarrays. Biochem. Biophys. Res. Commun.282:1263-1267.
Cited by
32 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Molecular Microecological Techniques;Advanced Topics in Science and Technology in China;2014
2. Rapid Oligonucleotide Suspension Array-Based Multiplex Detection of Bacterial Pathogens;Foodborne Pathogens and Disease;2013-10
3. References;Identifying Microbes by Mass Spectrometry Proteomics;2013-08-15
4. Profiling
In Situ
Microbial Community Structure with an Amplification Microarray;Applied and Environmental Microbiology;2013-02
5. Ecogenomic Sensors;Encyclopedia of Biodiversity;2013