Comparison of Serologic Assays for Detection of Antibodies against Human Herpesvirus 8

Author:

Corchero Jose L.1,Mar Eng-Chun1,Spira Thomas J.2,Pellett Philip E.1,Inoue Naoki1

Affiliation:

1. Division of Viral and Rickettsial Diseases1 and

2. Division of AIDS, STD, and TB Laboratory Research,2 National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia 30333

Abstract

ABSTRACT Improvement of serologic assays for detection of antibodies against human herpesvirus 8 (HHV-8) is critical to better understand its epidemiology and biology. We produced the HHV-8 latent (ORF73) and lytic (ORF65, K8.1, and glycoprotein B) antigens in the Semliki Forest virus system and evaluated their performance in immunofluorescence assays (IFAs) and enzyme-linked immunosorbent assays (ELISAs). These assays were compared with other latent antigen-based assays, including an IFA based on primary effusion lymphoma (PEL) cells and an ELISA based on bacterially expressed ORF73 antigen, as well as with other lytic antigen-based assays, including an IFA based on induced PEL cells, a commercial ELISA based on purified virions, and ELISAs based on K8.1- and ORF65-derived oligopeptides. We used a panel of 180 serum specimens obtained from three groups expected to have high, intermediate, and low HHV-8 prevalences. Using three different evaluation methods, we found that (i) the performances of the lytic antigen-based ELISAs were almost equivalent, (ii) the lytic antigen-based assays were more sensitive than the latent antigen-based assays, and (iii) in general, IFAs were more sensitive than ELISAs based on the same open reading frame. We also found that serum specimens from healthy individuals contained antibodies cross-reactive with HHV-8 glycoprotein B that can potentially cause false-positive reactions in lytic PEL-based IFAs. Although this is not a substantial problem in most epidemiologic studies, it may confound the interpretation of data in studies that require high assay specificity. Because the K8.1-based IFA provides sensitivity similar to that of lytic PEL-based IFAs and improved specificity, it can be a useful alternative to the PEL-based IFAs.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3