Intrinsic Bacterial Contamination of a Commercial Iodophor Solution: Investigation of the Implicated Manufacturing Plant

Author:

Berkelman Ruth L.1,Anderson Roger L.1,Davis Barry J.1,Highsmith Anita K.1,Petersen Norman J.1,Bond Walter W.1,Cook E. H.1,Mackel Donald C.1,Favero Martin S.1,Martone William J.1

Affiliation:

1. Hospital Infections Program, Center for Infectious Diseases, Centers for Disease Control, Atlanta, Georgia 30333

Abstract

After an outbreak of peritoneal infections attributed to intrinsic contamination of a poloxamer-iodine solution with Pseudomonas aeruginosa , the manufacturer of the contaminated solution permitted investigation and sampling of materials within the plant. Pseudomonas spp. were recovered from two different unopened lots of solution and from numerous water samples obtained at the plant. The isolates from water identical to those of an isolate recovered from Prepodyne solution (West-Agro Chemical Co., Inc., Westwood, Kans., manufactured for AMSCO Medical Products Div., Erie, Pa.) manufactured 1 month earlier at the same plant. P. aeruginosa was not recovered from incoming city water. P. aeruginosa was recovered from sterile water and poloxamer-iodine after 48 h of incubation in a plant polyvinyl chloride pipe. Scanning electron micrographs of polyvinyl chloride pipe used in the plant showed massive concentrations of rod-shaped and coccobacillary cells apparently embedded in interior deposits of the pipe. Manufacturers of iodophors should be aware that pipes or other surfaces colonized with bacteria may be a source of contamination of their products.

Publisher

American Society for Microbiology

Subject

Ecology,Applied Microbiology and Biotechnology,Food Science,Biotechnology

Reference16 articles.

1. American Public Health Association. 1982. Standard methods for the examination of water and wastewater. 15th ed. American Public Health Association Inc.. New York

2. Investigations into the survival of Pseuidomonas aeriuginosa in poloxamer-iodine;Anderson R. L.;Appl. Environ. Microbiol.,1984

3. Antibiotic susceptibility testing by a single disk method;Bauer A. W.;Am. J. Clin. Pathol.,1966

4. Pseudobacteremia attributed to contamination of providone-iodine with Pseiudotinonatis(epacia;Berkelman R. L.;Ann. Intern. Med.,1981

5. A rapid alkaline extraction procedure for screening recombinant plasmid DNA;Birnboim H. C.;Nucleic Acids Res.,1979

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献