Evaluation of the BioPlex 2200 Syphilis System as a First-Line Method of Reverse-Sequence Screening for Syphilis Diagnosis

Author:

Marangoni Antonella,Nardini Paola,Foschi Claudio,Moroni Alessandra,D'Antuono Antonietta,Bacchi Reggiani Letizia,Cevenini Roberto

Abstract

ABSTRACTDespite recent technological advances, the diagnosis of syphilis remains a challenging enterprise. Actually, most high-volume laboratories have adopted the “reverse algorithm” due several factors, including the potential to automate testing. Recently, immunoassays processed on random-access systems have been proposed as screening tests. The purpose of this study was to evaluate diagnostic performances of BioPlex 2200 Syphilis IgG and BioPlex 2200 Syphilis IgM, tests based on Multiplex Flow technology, in comparison with the performance of Architect Syphilis TP, a chemiluminescent immunoassay for the detection of IgG and/or IgM anti-Treponema pallidumantibodies. A retrospective study was performed with a panel of 100 blood donor sera, a panel of 350 clinical and laboratory-characterized syphilitic sera, and 170 samples obtained from subjects with potentially interfering conditions. Moreover, 200 unselected samples submitted to the Microbiology Laboratory of St. Orsola Hospital in Bologna for routine screening for syphilis were evaluated. As confirmatory tests,T. pallidumhemagglutination and Western blot assays were used. Considering the IgG Western blot (WB) assay to be the gold standard method, BioPlex 2200 Syphilis IgG specificity was far higher than Architect Syphilis TP specificity (89.7% versus 78.4%, respectively), whereas the sensitivity was 100% for both automated methods. Compared to the IgM WB assay, BioPlex 2200 Syphilis IgM performed with a specificity of 94.9%, whereas the sensitivity was 84.8%. Considering the excellent ease of use and automation, the high sample throughput and its valuable analytical performances, BioPlex Syphilis 2200 IgG could represent a suitable choice for high-volume laboratories. BioPlex Syphilis 2200 IgM could be considered a good addition to IgG testing for uncovering active infections.

Publisher

American Society for Microbiology

Subject

Microbiology (medical),Clinical Biochemistry,Immunology,Immunology and Allergy

Reference38 articles.

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3