Determination of Penicillin MICs for Streptococcus pneumoniae by Using a Two- or Three-Disk Diffusion Procedure

Author:

Jacobs Michael R.1,Bajaksouzian Saralee1,Palavecino-Fasola Elizabeth L.1,Holoszyc Henry M.2,Appelbaum Peter C.3

Affiliation:

1. Department of Pathology, Case Western Reserve University, and University Hospitals of Cleveland, Cleveland, Ohio 441061;

2. Giles Scientific, Inc., New York, New York 100112; and

3. Department of Pathology, Hershey Medical Center, Hershey, Pennsylvania 170333

Abstract

ABSTRACT The potential for the use of the disk diffusion method to accurately predict penicillin MICs for Streptococcus pneumoniae was investigated with penicillin (6 μg), methicillin (5 μg), and oxacillin (1 μg) disks. A total of 183 S. pneumoniae isolates were tested by three MIC procedures (agar dilution, microdilution, and E-test). Regression analyses of the geometric mean of the three MIC results against (i) the sum of the zone diameters for methicillin, penicillin, and oxacillin disks; (ii) the sum of the zone diameters for methicillin and penicillin disks; and (iii) each of the three individual zone diameters were performed. Calculated MICs were determined from each of these regression analyses and compared to the mean reference MICs. A high level of correlation was obtained with both the two- and the three-disk procedures ( r = 0.97), with essential agreement rates (±1 doubling dilution) between MICs calculated by the three-disk procedure and the two-disk procedure and the mean reference MICs of 98.4 and 98.9%, respectively. No major or very major errors were obtained with the two- or three-disk procedures. The accuracy of the disks used individually was lower ( r = 0.84 to 0.93). However, oxacillin and methicillin disk testing remain excellent for screening strains, with all penicillin-susceptible strains having zones of >21 and >22 mm, respectively. The combination disk procedure, which involves the use of three disks (methicillin, oxacillin, and penicillin) or two disks (methicillin and penicillin) for testing S. pneumoniae , can provide accurate penicillin MICs and qualitative category results that are comparable to results obtained by the E-test, agar, and microdilution MIC methods.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3