Multicenter Evaluation of the Performance Characteristics of the NucliSens HIV-1 QT Assay Used for Quantitation of Human Immunodeficiency Virus Type 1 RNA

Author:

Ginocchio Christine C.12,Kemper Marti3,Stellrecht Kathleen A.4,Witt Donald J.5

Affiliation:

1. Department of Laboratory Medicine, North Shore University Hospital-New York University School of Medicine, Manhasset

2. North Shore-Long Island Jewish Health System Laboratories, Lake Success

3. Center for Blood Research, Sacramento Medical Foundation, Sacramento, California

4. Department of Pathology and Laboratory Medicine, Albany Medical Center, Albany, New York

5. bioMérieux Inc., Durham, North Carolina

Abstract

ABSTRACT The analytical performance of the NucliSens HIV-1 QT assay, a highly sensitive test based on nucleic acid sequence-based amplification technology, was evaluated in a multicenter trial. Assay specificity was evaluated with 502 plasma (EDTA) specimens from human immunodeficiency virus type 1 (HIV-1)-seronegative volunteer donors. No HIV-1 RNA was reported in any of the donor specimens. Analytical sensitivity and reproducibility were estimated with panels prepared from a high-titer well-characterized HIV-1 RNA stock (5.84 × 10 8 RNA copies/ml). The assay's dynamic range was linear from 10 6 to 10 1 HIV-1 RNA copies, with a lower detectable limit of 25 copies/ml and a 95% detection rate of 176 copies/ml. Sensitivity of the assay to detect HIV-1 RNA in clinical specimens from patients ( n = 101) and in commercially available or prepared panels ( n = 24) was compared with NASBA HIV-1 RNA QT (an earlier version of NucliSens HIV-1 QT) and with the Food and Drug Administration-approved standard and ultrasensitive AMPLICOR HIV-1 MONITOR, version 1.0, assays. Detection of HIV-1 RNA was reproducible over a 5-log range (mean standard deviation = 0.15 log). The NucliSens and the standard AMPLICOR assays were equivalent in detection of HIV-1 RNA (concentration, 10 3 to 10 5 copies/ml) in 57 clinical specimens. The NucliSens assay was more sensitive in detecting HIV-1 RNA at lower concentrations (≤10 2 copies/ml) (44 of 44) than either the standard AMPLICOR test (12 of 19) or the NASBA assay (10 of 25). A 25% increase in HIV-1 RNA detection frequency with panels was observed with the NucliSens assay (23 of 24) compared with the standard AMPLICOR test (17 of 24). The new assay was highly specific and demonstrated good sensitivity with a broad linear dynamic range.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献