Author:
Liñares J,Sitges-Serra A,Garau J,Pérez J L,Martín R
Abstract
Our purpose was to study prospectively the causes, routes of infection, and frequency of catheter-related sepsis in patients on total parenteral nutrition. From January 1981 to January 1984, cultures of 135 subclavian catheters from 135 adult patients were done by quantitative and semiquantitative methods. Twenty patients (14.8%) had catheter-related sepsis. Fourteen episodes (70%) stemmed from an colonized hub. Skin infection (Staphylococcus aureus, 2 cases), total parenteral nutrition mixture contamination (Enterobacter cloacae, 2 cases), and hematogenous seeding of the catheter tip (Yersinia enterocolitica, 1 case, and Streptococcus faecalis, 1 case) accounted for the remaining six septic episodes. The catheter hub is, in our experience, the most common site of origin of organisms causing catheter tip infection and bacteremia.
Publisher
American Society for Microbiology
Reference24 articles.
1. Antibiotic susceptibility testing by a standardized single disk method;Bauer A. W.;Am. J. Clin. Pathol.,1966
2. Association between microorganisms growth at the catheter insertion site and colonization of the catheter in patients receiving total parenteral nutrition;Bjornson H. S.;Surgery,1982
3. A prospective study of subclavian vein catheters used exclusively for the purpose of intravenous feeding;Blackett R. L.;Br. J. Surg.,1978
4. Pathogenesis and predictability of central venous catheter sepsis;Bozzetti F.;Surgery,1982
5. Bacterial contamination of intravenous cannula injection ports and stopcocks;Brisman B.;Clin. Nutr.,1984
Cited by
335 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献