Accuracy of single radial hemolysis test for rubella immunity when internal reference standards are used to estimate antibody levels

Author:

Nommensen F E

Abstract

The accuracy and reproducibility of antibody levels obtained by single radial hemolysis with six internal reference sera were evaluated. The test was performed in a clinical laboratory for routine assessment of immunity to rubella infection over a period of 1 year. A linear relationship exists between the antibody titer (expressed in log dilution) and zone diameters. In 43 of 44 test runs the correlation coefficient of the standard curve was over 0.990. Prediction limits of 95% around the curve showed that on replication of the test, zone diameters could be found within less than half a doubling-dilution step. The antibody level can thus be determined more accurately by the single radial hemolysis test than in the conventional hemagglutination inhibition test. This is particularly important in assessing immunity when antibody titers are low, since the hemagglutination inhibition test is less reliable then. The use of standard sera calibrated international units would render results of different laboratories comparable and allow standardization at threshold values.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

Reference14 articles.

1. Hemagglutination inhibition, single radial hemolysis, and ELISA tests for the detection of IgG and IgM to rubella virus;Champsaur H.;J. Med. Virol.,1980

2. Draper N. R. and H. Smith. 1981. Applied regression analysis 2nd ed. p. 8-33. John Wiley & Sons Inc. New York.

3. Comparison of various serological methods and diagnostic kits for the detection of acute, recent, and previous rubella infection, vaccination, and congenital infections;Enders G.;J. Med. Virol.,1985

4. Standardization of techniques and reagents for the study of rubella antibody;Forsgren M.;Rev. Infect. Dis.,1985

5. Subclinical rubella reinfections in vaccinated women with rubella-specific IgM response during pregnancy and transmission of virus to the fetus;Forsgren M.;Scand. J. Infect. Dis.,1985

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Rubella;Remington and Klein's Infectious Diseases of the Fetus and Newborn Infant;2025

2. Standardization of Assays That Detect Anti-Rubella Virus IgG Antibodies;Clinical Microbiology Reviews;2016-01

3. Rubella;Infectious Diseases of the Fetus and Newborn;2011

4. Rubella;Infectious Diseases of the Fetus and Newborn Infant;2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3