One-Tube Real-Time Isothermal Amplification Assay To Identify and Distinguish Human Immunodeficiency Virus Type 1 Subtypes A, B, and C and Circulating Recombinant Forms AE and AG

Author:

de Baar Michel P.1,Timmermans Eveline C.2,Bakker Margreet13,de Rooij Esther12,van Gemen Bob2,Goudsmit Jaap13

Affiliation:

1. Department of Human Retrovirology, Academic Medical Center, University of Amsterdam,1

2. PrimaGen,2 and

3. Amsterdam Institute of Viral Genomics,3 Amsterdam, The Netherlands

Abstract

ABSTRACT To halt the human immunodeficiency virus type 1 (HIV-1) epidemic requires interventions that can prevent transmission of numerous HIV-1 subtypes. The most frequently transmitted viruses belong to the subtypes A, B, and C and the circulating recombinant forms (CRFs) AE and AG. A fast one-tube assay that identifies and distinguishes among subtypes A, B, and C and CRFs AE and AG of HIV-1 was developed. The assay amplifies a part of the gag gene sequence of the genome of all currently known HIV-1 subtypes and can identify and distinguish among the targeted subtypes as the reaction proceeds, because of the addition of subtype-specific molecular beacons with multiple fluorophores. The combination of isothermal nucleic acid sequence-based amplification and molecular beacons is a new approach in the design of real-time assays. To obtain a sufficiently specific assay, we developed a new strategy in the design of molecular beacons, purposely introducing mismatches in the molecular beacons. The subtype A and CRF AG isolates reacted with the same molecular beacon. We tested the specificity and sensitivity of the assay on a panel of the culture supernatant of 34 viruses encompassing all HIV-1 subtypes: subtypes A through G, CRF AE and AG, a group O isolate, and a group N isolate. Assay sensitivity on this panel was 92%, with 89% correct subtype identification relative to sequence analysis. A linear relationship was found between the amount of input RNA in the reaction mixture and the time that the reaction became positive. The lower detection level of the assay was approximately 10 3 copies of HIV-1 RNA per reaction. In 38% of 50 serum samples from HIV-1-infected individuals with a detectable amount of virus, we could identify subtype sequences with a specificity of 94% by using sequencing and phylogenetic analysis as the “gold standard.” In conclusion, we showed the feasibility of the approach of using multiple molecular beacons labeled with different fluorophores in combination with isothermal amplification to identify and distinguish subtypes A, B, and C and CRFs AE and AG of HIV-1. Because of the low sensitivity, the assay in this format would not be suited for clinical use but can possibly be used for epidemiological monitoring as well as vaccine research studies.

Publisher

American Society for Microbiology

Subject

Microbiology (medical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3